RS-5 Jan. 2001
8
However, the following system setup parameters will not be
transmitted via bulk dump.
Rx SysEx Sw
Device ID#
LCD Contrast
All:All five of the above settings (The SYSEX of Use Tone will
not be output for Version Number of ROM. Please refer to
the Service information No.10134a [Ver.1.03])
1. Use a MIDI cable to connect the RS-5's MIDI OUT connector
to the MIDI IN connector of the external sequencer.
2. Press [UTILITY], getting the indicator to light.
3. Use VALUE [-]/[+] to select "Bulk Dump."
4. Press [ENTER].
5. Use the VALUE [-]/[+] to select the types of Bulk Dump.
6. Put the external sequencer in record mode.
7. Press [ENTER] to transmit the settings.
The message "Transmitting..." appears in the display during
transmission of the data.
* Do not press any key on the keyboard while Bulk Dump is in
progress. Pressing a key sends Note messages from the MIDI
OUT connector. To cancel the Bulk Dump, press [EXIT].
After the transmitting is finished, the display will indicate
"Completed."
The [UTILITY] indicator goes out, and you are returned to the
previous screen.
8.Stop the external sequencer.
How to data load
Setting the System Exclusive Receive Switch
When returning saved settings to the RS-5, set the Exclusive
Receive switch to ON. With the factory settings, this will be "ON."
1. Press [EDIT], getting the indicator to light.
2. Use VALUE [-]/[+] to select "System Setup."
3. Press [ENTER].
4. Press the numeric key [4] several times to select "System
Exclusive."
* If you hold down [SHIFT] and press [4], you will return to the
previous item.
5. Use VALUE [-]/[+] to set "ON."
6. Press [EDIT].
The [EDIT] indicator goes out, and you are returned to the
previous screen.
Restoring saved settings to the RS-5
* Be aware that when you restore data to the RS-5, the data in the
RS-5 will be overwritten and lost.
1. Use a MIDI cable to connect the MIDI OUT connector of the
external sequencer to the MIDI IN connector of the RS-5.
2. Set the device ID number to the same setting as when you
performed the bulk dump.
System Setup Numeric Key [4] : Device ID
(refer to "
Setting the Device ID Number")
3. Turn on the exclusive receive switch.
System Setup Numeric Key [4] : System Exclusive
(refer to "
Setting the System Exclusive Receive Switch")
4. Transmit (play back) the data from the external sequencer.
When the transmitting is finished, you are returned to the
previous screen.
* Play back the external sequencer at the same tempo you used
when performing the bulk dump. If you use a faster tempo, the
data may not be restored correctly.
Caution:
When data is being written to the User Memory, the message
"KEEP POWER ON!" appears in the display; be sure not to turn off
the power while this message is displayed.
If the power is turned off or interrupted while data is being written
to memory, the internal data may become corrupted, and you may
not be able to turn the power back on. If you have confirmed that,
Upgrade (refer to "Upgrading the program memory software
version") and execute the Factory Reset (refer to "Factory Reset
procedure")