STORM BAR SHOWER VALVE
STORM BAR SHOWER VALVE
SV2208
STORM BAR SHOWER VALVE
STORM BAR SHOWER VALVE
SV2207
TMV2 / Buildcert Ref No: RRTAV10
TMV2 / Buildcert Ref No: RRTAV9
REF: KH.RR.BSV10 | 07.10 V3.00
FACTOR BAR SHOWER VA
FACTOR BAR SHOWER VA
LVE
LVE
SV1308
FACTOR BAR SHOWER VALVE
FACTOR BAR SHOWER VALVE
SV1307
TMV2 / Buildcert Ref No: RRTAV8
TMV2 / Buildcert Ref No: RRTAV11
Customer Services, Roper Rhodes Ltd, Brassmill Lane Trading Estate, Bath, BA1 3JF
TEL: 01225 303 900 | FAX: 01225 448 877
Email: sales@roperrhodes.co.uk | Web: www.roperrhodes.co.uk
STORM & FACTOR
STORM & FACTOR
THERMOSTATIC SHOWER BAR VALVE
THERMOSTATIC SHOWER BAR VALVE
Installation & aftercare instructions
Please retain for future reference
SERVICE INTERVALS
Subsequent frequency can be determined with reference to previous test results. Where no significant deviation was
recorded the test interval can be made equal to the maximum recorded interval to that point.
Note. Check valve and strainer servicing must be conducted at each test interval.
If the recorded mixed water temperature is greater than > 2°K from the initial recorded settings or the set point cannot
be reached / stabilised further action is required.
It is important to establish that the incoming water supplies still satisfy the initial guidance and also that no additional
draw off variation that could affect performance has occurred.
The material selection for this valve has excellent resistance to scale build up and is designed such that there are no
serviceable parts beyond items 1 & 2 as described previously.
In the very unlikely event that initial performance cannot be achieved, and all external parameters are correct, the unit
may require replacement.
10-YEAR GUARANTEE
We have complete confidence in this Roper Rhodes product and as such it is offered with a 10-year guarantee against
defects in manufacture. The guarantee requires that this product be used in the manner for which it was intended and
that it is installed & maintained in accordance with the fitting instructions and local water bylaws. The guarantee
covers products in domestic use only.
The guarantee is invalidated should the valve be damaged by water borne debris. Make sure that supply pipes are clear
of any debris prior to installation, this is particularly important on new plumbing installations.
In the unlikely event that this product should fail during the guarantee period we will either replace the faulty part or the
complete unit as appropriate.
Question and Answer IconNeed help?

Do you have a question about the Roper Rhodes SV2207 and is the answer not in the manual?

Roper Rhodes SV2207 Specifications

General IconGeneral
BrandRoper Rhodes
ModelSV2207
CategoryPlumbing Product
LanguageEnglish

Summary

Service Intervals

10-Year Guarantee

Introduction and Operating Conditions

Conditions of Use for Type 2 Valves

Specifies operating conditions like pressure and temperature for Type 2 valves.

Aftercare and Maintenance

Commissioning Procedures

Record Water Temperatures and Pressures

Documents temperature and pressure readings for commissioning.

Cold Water Failure Test

Tests the valve's reaction to cold water supply isolation.

Maintain Commissioning Records

Emphasizes keeping records for the valve's service life.

In-Service Testing and Maintenance

Initial Performance Check (6-8 Weeks)

Re-tests performance after initial installation and checks.

Subsequent Performance Check (12-15 Weeks)

Checks for drifts from initial settings after initial service.

Installation Guidelines and Compliance

Ensure Accessibility for Servicing

Valve must be installed for easy access for testing and servicing.

Flush Pipework Before Installation

Crucial step to prevent debris from causing operational problems.

Water Supply Regulations and Valve Specifications

Water Supply (Water Fittings) Regulations 1999 Compliance

Confirms valve complies with relevant water supply regulations.

Mounting Dimensions and Temperature Setting

Details valve mounting and factory set maximum outlet temperature.