To change the Unit from °C to °F:
1. Turn off the device.
2. Hold down the “Start” button, then press and
hold the“ON/OFF/Memory” button until the LCD
shows °C.
3. Press the “Start” to change the °C to °F, then
release the “Start” button.
4. During the setting adjustment, each old or new
temperature scale setting will be ashing for 6
seconds. After 6 seconds without changing, the
temperature scale adjustment will be completed,
and the unit will be entered into measurement
mode.
b. Replace the probe cover after each use to ensure an accurate
reading and avoid cross contamination.
c. This thermometer must only be used with rossmax probe
covers, other covers can lead to inaccuracy. If running out
of probe covers, please contact with the original seller or dis-
tributor for buying new probe covers.
4. Measuring the ear temperature: Use the index nger to trigger, by
pressing “Start” button, a long beep will be sounded when meas-
urement is done.
5. For the next measurement, remove the used probe cover and put
on a new one.
6. Power off: If left idle for more than 1 minute, device will automati-
cally shut off for extending battery life. Or press “On/Off/Memo-
ry” button for at least 3 seconds to turn the device off.
7. Fever alarm: When the measuring temperature is higher than 37.5
°C(93.2°F), the reading will ash, the backlight will be enabled, and
4 short beeps will be sounded. If measuring temperature is higher
than 42.2 °C(108°F), the display will show “Hi”, the backlight will
be enabled, and 4 short beeps will be sounded.
a. It is recommended that you measure 3 times with the same
ear within a short period of time. If the 3 consecutive meas-
urements are different, select the highest temperature.
b. To avoid the risk of cross contamination, please clean the probe
according to “Clean and Storage“ section after each use.
www.rossmax.com
LCD
display
Battery
cover
ON/OFF/
Memory
button
Probe
Ear Battery
Probe
cover
°C/°F scale
Temperature
display
Probe
cover
Clockwise
way to lock
Probe
Instruction Manual
Model: RA600
1. To achieve accurate readings, make sure a new, clean probe cover is
in place before each measurement and the ear canal is clean.
a. Install the probe cover by clockwise rotating then x it.
b. Remove the probe cover by anti-clockwise rotating then releas-
ing it.
2. Press the “On/Off/Memory” button, the thermometer is ready
for use after the ear icon is ashing, two beeps are sounded, and
three dash segments are appeared.
3. Gently pull the ear back to straighten the ear canal and snugly posi-
tion the probe into the ear canal, aiming towards the membrane of
the eardrum to obtain an accurate reading.
a. Before measurement, correct installation of the probe cover
ensures accurate measurement.
There are total 9 set memories for measurement records. If the read-
ing of the thermometers is within the normal temperature range of
34 °C to 42.2 °C (93.2 °F to 108°F ), when the measurement is done,
the measurement data is saved into memory.
Press “On/Off/Memory” button to repeatedly to recall each tem-
perature memory.
It means measurable and reminds to use a probe cover for
measurement.
When battery icon always appears, please replace the battery.
How to use the RA600 Infrared Ear Thermometer
LCD display
Memory function
Cleaning and storage
Please read the instruction manual carefully before using the
product and be sure to keep this manual.
1. Turn off the device.
2. Hold down the “Start” button, then press and hold the“ON/OFF/
Memory” button until the LCD shows °C.
3. Press the “ON/OFF/Memory” change beep sound from on to off, then
release the “ON/OFF/Memory” button.
4. After 6 seconds without changing, the beep On/Off setting will be
completed, and the unit will be entered into the measurement mode.
Enabling or disabling the beep sound
The Rossmax Infrared Ear thermometer has been carefully devel-
oped for accurate, safe and fast temperature measurements in the
ear.
It is a non-invasive ear thermometer using an infrared detector to
detect body temperature from the auditory canal for adult and
child.
The quality of the infrared ear thermometer has been veried and con-
forms to the provisions of the EC council directive 93/42/EEC(Medical
Device Directive) Annex I essential requirements and applied harmo-
nized standards. EN 12470-5: 2003 Clinical thermometers-Part 5: Per-
formance of infrared ear thermometers (with maximum device.)
This thermometer converts the ear temperature to display its “oral
equivalent.” (according to the result of the clinical evaluation)
RA600 Infrared Ear Thermometer
Switching between temperature scale
Fahrenheit and Celsius
1. This thermometer is equipped with one lithium cell (CR2032).
2. Turn off the thermometer before replacing the battery.
3. Open the battery cover: Hold the device and ip the battery out
by sticking the pen tip into the battery storage well as illustrated.
4. Insert a new battery and ensure the battery positive polarity is
facing upward.
5. Place back the battery cover.
* The positive (+) side up and the negative (-) side pointed down.
Change the battery
Probe
cover
Start
button
Error message Problem Solution
bi-bi-bi
The ambient tem-
perature is not
within the range
between 10°C~40°C
(50°F~104°F)
Allow the thermometer
to keep in a room for at
least 30 minutes at room
temperature: 10°C to
40°C (50°F to 104°F)
bi-bi-bi
The system is not func-
tioning properly.
Unload the battery, wait
for 1 minute and re-
power it. If the message
reappears, contact the
retailer for service.
Device can not be pow-
ered on to the ready
stage.
Change with a new bat-
tery. If the message reap-
pears, contact the retailer
for service.
bi-bi-bi-bi
Temperature taken is
higher than 42.2°C
(108.0°F)
Ensure no break or dirt
of the probe cover and
take a new temperature
measurement.
bi-bi-bi-bi
Temperature taken
is lower than 34°C
(93.2°F)
Make sure the probe
cover is clean and take a
new temperature meas-
urement.
Troubleshooting
EN
If you continuously obtain different measurement results, it is recom-
mended that you use Scanning Mode to measure.
Measuring the ear temperature: Use the index nger to trigger, press
and hold the “Start” button for 3 seconds to take measurement.
During the measuring process, gently pivoting the probe side-to-side
to view the entire ear canal or in order to nd the highest tempera-
ture. Release the “Start” button until hearing a long beep sound and
the measurement is completed.
Scanning Mode
The probe is the most delicate part of the thermom-
eter. Use with care when cleaning the lens to avoid
damage.
1. Please use the cotton swab with the Alcohol to clean
the lens (on the inside of the probe).
2. Allow the probe to fully dry for at least 5 minutes.
a. Please check the device if it falls and damages. If you can’t
make sure of it, please send the complete device to the
nearest retailer for recalibration.
b. Keep the unit dry and away from any liquid and direct sun-
light. The probe should not be submerging into liquids.

Other manuals for Rossmax RA600

Question and Answer IconNeed help?

Do you have a question about the Rossmax RA600 and is the answer not in the manual?

Rossmax RA600 Specifications

General IconGeneral
TypeDigital Thermometer
DisplayLCD
Fever AlarmYes
WaterproofNo
Auto Power OffYes
Measurement Range32.0°C to 42.9°C
Accuracy±0.2°C (±0.4°F)
Measurement SiteOral, Rectal, Axillary
BatteryLR41 or SR41
MemoryLast reading recall