What to do if Rotary Lifting columns show Emergency Stop?
- WWilliam SmithAug 15, 2025
To restore operation of your Rotary Lifting columns, clear the emergency stop button at the indicated column.

What to do if Rotary Lifting columns show Emergency Stop?
To restore operation of your Rotary Lifting columns, clear the emergency stop button at the indicated column.
What to do if Rotary MCH418 Lifting columns display a Communication Error?
First, check for any loosened or unhooked communication cables and reattach if necessary. Then press “x” to clear the error. Also, verify that all columns are powered on. If one column has been powered down, power down the other columns to re-initialize the system.
What to do if Rotary MCH418 Lifting columns detect a Short circuit?
Press “x” to clear the error. To find the faulty component in your Rotary Lifting columns, run the column by itself and follow these steps until the error reappears: 1) While not operating (Error? Check/replace contactor) 2) Up button (Error? Check/replace contactor) 3) Slow lower (Error? Check/replace small lowering valve) 4) Lower to locks (Error? Check/replace large lowering valve) 5) Down button (Error? Check/replace lock solenoid.
What to do if Rotary Lifting columns are Out of Level?
Press “x” to clear the error. Then, individually adjust each Rotary Lifting column back to a level position. Once all columns are level, they can be moved as a group.
What to do if Rotary Lifting columns display is Unresponsive?
Turn off the power to your Rotary Lifting columns. Check the wire connections on the display board for the keypad, pushbuttons, and control board. Restart the power and test the display.
What to do if Rotary MCH418 Lifting columns have Improper configuration?
Press “x” to clear the error on your Rotary Lifting columns. To add the column to the system, first power down the column, and then unlock the system. Power up the column, assign a position, then re-lock the system.
Why are my Rotary Lifting columns Slow To Rise?
Your Rotary Lifting columns might be slow to rise due to being overloaded, or there might be an issue with the battery and connections, or dirt/debris in the oil system. Check these potential causes.
What to do if Rotary Lifting columns show a Software mismatch?
Power down and disconnect the affected Rotary Lifting column from the system. Load the column with the newest software code. To check the software revision level, insert a service card. The revision level is indicated in the service menus as “r__.”
What to do if Rotary Lifting columns show a CPU error?
Press “x” to clear the CPU error on your Rotary Lifting columns. If the problem continues, call for service.
| Brand | Rotary |
|---|---|
| Model | MCH418 |
| Category | Lifting columns |
| Language | English |
Essential safety rules for personnel operating the automotive lift.
Critical procedure for safely lowering the lift without electrical power.
Procedure for safely de-energizing the lift for maintenance or repair.
Step-by-step instructions for basic lift operation and vehicle positioning.
Detailed procedures for safely raising and lowering the vehicle.
Critical safety warnings and guidelines for using the battery charger.
Loading...