RPBS-1 PORTABLE SCALE 2.0 8
7. Use the UP and DOWN arrow buttons to select the “CLEAR ALL”
message and press the SELECT button. The message “SURE no”
appears.
8. Select “CLEAR LAST” to clear only the last weight.
9. Use the UP and DOWN directional arrow buttons to select the “SURE
YES” message and press the SELECT button.
NOTE: The RPBS-1 history is erased without calibration alteration.
10. To double-check the RPBS-1 calibration, place a known weight on the
weighing basket and check the results.
11. When the unit is accurate, repeat Steps 7-9 to clear the weighing
history.
12. To recalibrate the RPBS-1, see Scale Calibration on page 8.
NOTE: The RPBS-1 queries you to perform the tare procedure after every power on,
300 weights or changing a flock/house/farm.
To not perform the tare procedure, take the first weight measurement without
pressing on the TARE button and the message stops.
Scale Calibration
This procedure should be performed only if the RPBS-1 does not display
the correct weight of a known weight. Scale calibration should also be
preformed after every Cold Start.
To calibrate the RPBS-1 scale:
1. Press the UP directional arrow and TARE buttons. The message
“TARE/CALIB” appears.
2. Press the SELECT button. The RPBS-1 performs a tare procedure to
prevent a negative calibration.
3. Place a known weight on the weight scale pan and use the UP and
DOWN directional arrow buttons to set the weight for the known weight.
4. Press the SELECT button. The RPBS-1 performs a calibration and the
message “GOOD Calibration” is displayed.
5. If the message “BAD Calibration” appears repeat Steps 1-4.
6. Press the SELECT button to exit.