EasyManua.ls Logo

Roughneck 57133 - User Manual

Roughneck 57133
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
W
INST
R
preca
u
20V
H
W
ARNING
R
UCTIONS b
u
tions may r
e
READ
&
H
eav
y
:
Read care
f
efore opera
t
e
sult in serio
u
It
e
&
SAVE
y
-Dut
Gasoli
Own
f
ully and un
d
ing. Failure
t
u
s personal
i
e
m #57
1
THESE
I
y Fu
e
ne Co
m
er’s M
a
d
erstand all
A
t
o follow the
i
njury.
1
33
I
NSTRU
C
e
l Tr
a
mp
atible
a
nual
A
SSEMBLY
safety rules
C
TIONS
a
nsfe
r
AND OPER
A
and other b
a
r
Pu
m
A
TION
a
sic safety
m
p

Questions and Answers

  • T
    Tiffany HansenAug 11, 2025
    How to fix a Roughneck 57133 when the motor is not turning?
    • L
      Lori JohnsonAug 11, 2025
      If the motor of your Roughneck Water Pump is not turning, consider the following: * **Lack of electric power:** Check the electrical connections and the safety systems. * **Rotor jams:** Check for possible damage or obstruction of the rotating components. * **Thermal overload protection shut:** Move the ON/OFF lever to the “OFF” position to reset the pump. * **Motor problems:** Contact with the service department.
  • F
    fitzgeraldwendyAug 20, 2025
    Why is my Roughneck 57133 making increased noise?
    • A
      Alex MedinaAug 20, 2025
      Increased noise in your Roughneck Water Pump can be due to: * **Cavitations occurring:** Reduce suction pressure. * **Irregular functioning of the by-pass:** Dispense until the air is purged from the circuit. * **Air present in the diesel fuel:** Verify the suction connections.
  • J
    jenniferyorkAug 27, 2025
    What causes leakage from the Roughneck 57133 Water Pump body?
    • R
      Randy PerezAug 27, 2025
      Leakage from the Roughneck Water Pump body is often caused by a damaged seal. Check and replace the mechanical seal.
  • M
    Michael HansenNov 3, 2025
    What to do if my Roughneck 57133 has low or no flow rate?
    • S
      Steven MyersNov 3, 2025
      If your Roughneck Water Pump has low or no flow rate, here are some possible causes and solutions: * **Low level in the suction tank:** Refill the tank. * **Foot valve blocked:** Clean and/or replace the valve. * **Filter clogged:** Clean the filter. * **Excessive suction pressure:** Lower the pump with respect to the level. * **High loss of head in the circuit:** Use shorter tubing or tubing with a greater diameter. * **By-pass valve blocked:** Dismantle the valve, then clean and/or replace it. * **Air entering the pump or the suction tubing:** Check the seals of the connections. * **A narrowing in the suction Tubing:** Use tubing suitable for working under suction pressure. * **Low rotation speed:** Check the voltage at the pump, adjust the voltage, and/or use cables o...

Summary

Intended Use

Packaging Contents

Technical Specifications

Electrical Specifications

Details the electrical power requirements and flow rates for the pump.

Important Safety Information

Work Area Safety

Guidelines for maintaining a safe work environment around the pump.

Personal Safety Precautions

Essential personal safety measures for operating the pump.

Pump Use and Care

Specific Operation Warnings

Main Parts of Product

Assembly Instructions

Before Each Use

Operating Instructions

After Each Use

Maintenance

Troubleshooting

Parts Diagram

Parts List

Replacement Parts

Limited Warranty

Roughneck 57133 Specifications

General IconGeneral
Max. Flow Rate158 GPM
Max. Total Head98 ft.
Max. Suction Lift26 ft.
Max Flow Rate158 GPM
Max Head98 ft.
Power2.5 HP

Related product manuals