Troubleshooting
Problems
Possible cause
Remedy
The machine is not
working
The machine is not connected to the
wall socket
Connect the machine
The power switch is open
Restart it after repositioning
The machine does not
work in cleaning mode
The connecting cable is disconnected
Check and fasten the wire.
The rammer motor has broken down
Repair or replace the beater motor
The mini circuit breaker was
damaged.
Find and fix the problem, then
reposition it
The machine does not
work in automatic mode
The function switch wire is
unplugged
Check and fasten the wire.
There is a problem with the control
panel
Change the control panel.
The compressor is not
working
Low voltage
Solve the problem of low voltage
The contactor is broken
Change contactor
The compressor relay has broken
Change the control panel.
There is a problem with the control
panel.
Change the control panel.
Compressor self-protection against
overload.
Find and solve the problem
The compressor is broken
Change compressor
The compressor capacitor has
broken
Change the capacitor
The machine does not
freeze
Refrigerant leakage
Find and repair the leak in the pipe,
then vacuum and add refrigerant
The electric valve is broken
Change the electric valve
Fan motor not working
Repair or replace fan motor
The fan motor capacitor has broken
Change the fan motor capacitor
The machine freezes all
the time
The setpoint is too low
Increase the setting
There is a problem with the control
panel.
Change the control panel
Refrigeration difference
Check and repair the refrigeration
system
The relay is not stable
Low voltage
Solve the problem of low voltage
There is a problem with the control
panel.
Change the control panel.
The touch point of the contact
switch is broken.
Remove the touch point or change
the contact switch.
The product does not
have a dispenser
The mixture ratio is incorrect and
causes a difference in cooling
Prepare the appropriate
proportion of the mixture.
No mixture in the tank
Pour the mixture into the hopper
The limit switch is damaged or the
cable is loose.
Change the switch or attach the
cord
The belt is loose or slipping
Change or adjust the belt
Worn bearing bush or tamper shaft
Replace the bearing bush or
tamper shaft.
Product too soft
The proportions in the formula are
incorrect
Mix the mixture according to the
recipe provided by the supplier.
The setpoint is too low
Increase the setting