When placing the replace or building the wall structure, please place the insert in dry, safe
and clean place.
4. If there is no satisfactory socket near the selected position, please ask a professional electrician
to install the socket behind or near the frame as per requirement.
WARNING
Do not install an electric circuit or socket arbitrarily in order to prevent re accidents, elec-
tric shock or physical injury. Please ask a professional electrician to install the circuit.
1. Turn off the switch on the core of the replace.
2. Insert the power plug into AC230V/15A socket. The cable should be laid along the wall.
3. Pull the core of replace into the frame or the wall structure until it parallels with the panel or
wall.
4. Finish the installation ensuring that the power plug is accessible after installation.
5. Level the re by adjusting the feet.
Note
If necessary, the proles on the side of the unit can be easily removed by removing the two
screws.
MAINTENANCE
Warning
Before cleaning and repairing the electric replace, please pull out the power plug to pre-
vent re accidents, electric shock or physical injury.
Relling Water
1. When there is no mist, or you hear the water shortage alarm, please rell the water tank imme-
diately. (It’s acceptable to use a small amount of non-toxic fragrance for better scent.)
2. When the water no longer covers the atomization sheet, atomization stops in 3 seconds and
there will be no ame effect.
3. When the atomizer stops, please turn all controls off, unplug the appliance, rell the water tank,
plug back in and restart.
15. If the heating unit becomes overheated, the replace will make a warning sound or a warning
light will ash. In this case, please turn off the heating unit immediately and check whether the elec-
tric replace is near any objects that may have caused it to overheat as listed in points 2 and 12.
Do not continue using the electric replace if any warning sign is shown.
16. Do not burn wood or other materials inside the electric replace.
17. Do not hit the glass of replace.
18. Please use the socket with excellent earth, fuse and earth electrode.
19. Please pull out the power plug when cleaning, maintaining or removing the replace.
20. Please keep the replace and wiring dry when transporting or storing them (remove the water
before moving the replace). Avoid strenuous vibration to prevent damage to the replace.
21. In order to avoid overheating, do not cover the heater.
22. The heater must not be located immediately below a socket-outlet.
23. When you are not using the unit for a longer period of time or if you want to transport please
empty the container
INSTALLATION
This section is the guidance for electric replace installation
Leave a clearance of at least 1cm between the replace recess and the surround of the replace to
ease installation.
The electric replace does not need a ue.
Warning
1. The power socket shall be AC230V/15A three-core socket with excellent earth, fuse and earth
leakage protection.
2. Note:
In order to avoid overheating, do not cover the heater. Do not scrape the plastic off the core of
replace or install the core directly on a soft surface. Otherwise, it may block the air circulation and
cause re accidents.
Install the electric replace in dry and safe places free from dust and ammable articles. Please
ensure that objects such as curtains not to block the outlet.
3. It is possible that the ames become lower when the heating function is switched on. This can be
prevented by placing the surround 10 mm from the wall.
Reminder
1. It is advisable to install the electric replace near the socket to ease electric installation.
2. First place the electric replace on the selected position to see whether it is satisfactory.
3. This electric replace is not allowed to be installed directly onto a wall. Place the mantel in the
desired location or build a replace recess in the desired location on the oor near the wall. The
size of the recess should be:
Model
Specication of The Opening
W H D
MF1530H 45.0cm 66.0cm 26.0cm
MF1510 63.5cm 68.5cm 26.0cm