Disconnect power before installing or servicing the pump.
Our pump is equipped with silicone blocked, tin coated 16 gauge (1.5 mm
2
) wire.
Please follow the table below when extending the wires.
Electrical
Recommended Wire Size
Total Wire Length (positive to pump to ground) - feet (meters)
0-6 ft
(0-1.8 m)
16 AWG
(1.5 mm
2
)
6- 10 ft
(1.8 - 3 m)
14 AWG
(2.5 mm
2
)
10 - 15 ft
(3 - 4.6 m)
12 AWG
(4 mm
2
)
15 - 30 ft
(4.6 - 5.5 m)
10 AWG
(6 mm
2
)
30 - 40 ft
(5.5 - 12.2 m)
8 AWG
(10 mm
2
)
This pump must be fused as follow:
All potential sources of ignition located in spaces containing gasoline powered
machineryorgasolinefueltank(s),orjointtting(s),orotherconnection(s),between
components of a gasoline system, shall be ignition protected in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
The electrical wiring, connections, and installation shall be in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
3
The electrical wiring, connections, and installation shall be in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
GPH (LPH) Volts Amps (Volts)
Amps
(Volts)
Fuse Size
12 Volts
360 (1363) 12 2.1 (12) 2.4 (13.6) 4 A
500 (1893) 12 1.6 (12) 1.8 (13.6) 4 A
800 (3028) 12 3.4 (12) 4.3 (13.6) 7.5 A
1100 (4164) 12 3.7 (12) 4.7 (13.6) 7.5 A
24 Volts
500 (1362) 24 1.0 (24) 1.2 (27) 3 A
800 (3028) 24 1.7 (24) 2.0 (27) 4 A
1100 (4164) 24 1.9 (24) 2.2 (27) 4 A