EasyManua.ls Logo

Runxin F79A-LCD - Page 13

Default Icon
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL 82602-F79A-LCD/82602B-F79B-LCD/82604-F82A-LCD/82604B-F82B-LCD
10
○,4 Pipeline connection
a. As Figure 1-3 shows, install a
pressure gauge in water inlet.
b. Install valve A, valve B, valve C
and valve D in the inlet and outlet
pipeline. The valve D is sampling
valve. (Or adopt F70C/F70D bypass
valve). (Can remove the check
valve.)
c. Inlet pipeline should be in parallel
with outlet pipeline. Support inlet
and outlet pipeline with fixed holder.
Note:
If making a soldered copper
installation, do all sweat
soldering before connecting
pipes to the valve. Torch heat will
damage plastic parts.
When turning threaded pipe
fittings onto plastic fitting, use care not to cross thread or broken
valve.
If the valve belongs to time clock type or F79, there are no step
and
○,5 Install drain pipeline
a. As the Figure 1-4 shows, slide the drain hose connector into drain outlet.
b. Insert drain line flow control into drain outlet.