MODEL 82602-F79A-LCD/82602B-F79B-LCD/82604-F82A-LCD/82604B-F82B-LCD
30
could be set F-00. That is, backwash in each regeneration; when the
turbidity is lower, the interval backwash time could be set F-01 (or other
number value), it is to say that backwash in every two regeneration. Thus,
Service→Brine& Slow rinse→Brine refill→ Fast rinse→ Service→
Backwash →Brine& Slow rinse →Brine refill →Fast rinse.
⑧ Regeneration time: The whole cycle for generation is about two hours.
Please try to set up the regeneration time when you don’t need water
according to the actual situation.
The above calculation of parameters for each step is only for reference,
the actual proper time will be determined after adjusting by water
exchanger supplier. This calculation procedure of softener is only for
industrial application; it is not suitable for small softener in residential
application.