Installation
Gas adjustment
Before any adjustment is started the gas and electricity supply to the appliance
must be turned off.
Change the injector of the burners
• Remove the pan support, burner cover and flame spreader
• Unscrew the injector using a spanner and replace it with the stipulated injector
for the new gas supply.
• Carefully reassemble all of the components.
• After the injectors are replaced, you must ensure the replacement injectors
are fully tightened.
Adjustment of the minimum flame level
• Turn the taps down to the minimum level
• Remove the dial from the tap and place a small bladed screw driver in the
centre of the tap shaft
• The correct adjustment is obtained when the flame has a length of 3mm - 4mm
(for butane/propane gas the adjustment screw must be tightly screwed in).
For Customer Services & Spare Parts please call 0345 208 8750
Opening times: Monday - Friday 8am – 8pm & Saturday 9am – 1pm
or visit us at www.productcare.co.uk
12
Injector