Installation
Refit the dial and make sure that the flame does not go out by quickly turning
from maximum flame to minimum flame. If it does then remove the dial and
make further adjustments to the gas flow, testing it again once the adjustment
has been made.
Repeat this process for each one of the dials/gas taps
Note:
Do note dismantle the tap shaft, in the event of a malfunction change the
whole tap.
Before placing the burners back, make sure that the injector is not blocked.
A full operational test and leakage test must be carried out after a gas
conversion.
After completing a conversion a qualified installer must mark a “V” on the
correct gas category to match with the setting in the rating label (remove the
previous “V” mark
For Customer Services & Spare Parts please call 0345 208 8750
Opening times: Monday - Friday 8am 8pm & Saturday 9am 1pm
or visit us at www.productcare.co.uk
13
Dial
Tap
Sealing ring
Adjustment screw