EasyManua.ls Logo

Ruud 801S SERIES - User Manual

Ruud 801S SERIES
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ISO 9001:2008
INSTALLATION INSTRUCTIONS
FOR UPFLOW/HORIZONTAL SINGLE STAGE
GAS FURNACES
(-)801S UPFLOW/HORIZONTAL SERIES
(-)801P UPFLOW/HORIZONTAL SERIES AND
(-)(-)801MSS UPFLOW/HORIZONTAL SERIES
(-)(-)801MSP UPFLOW/HORIZONTAL SERIES
U.L. and/or C.S.A. recognized fuel gas and CO (carbon monoxide) detectors are rec-
ommended in all applications, and their installation should be in accordance with the
manufacturer’s recommendations and/or local laws, rules, regulations, or customs.
92-24161-142-01
SUPERSEDES 92-24161-142-00
Factory Use Only
ST-A1220-01-X0

Questions and Answers

Summary

General Information

Furnace Components

Identifies key components of the furnace with item numbers.

Safety Information

Important Information About Efficiency and Indoor Air Quality

Discusses the importance of proper airflow and duct system for efficiency and indoor air quality.

Location Requirements

Site Selection

Guidelines for selecting an appropriate installation site for the furnace.

Clearance - Accessibility

Specifies required clearances to combustibles and for service access.

Ducting

Upflow Installations

Instructions for installing the furnace in an upflow duct configuration.

Horizontal Units

Instructions for installing the furnace in a horizontal configuration.

Combustion and Ventilation Air

Combustion Air Requirements

Details requirements for providing adequate air for combustion and ventilation.

Furnace Located in a Confined Space

Requirements for combustion air when the furnace is in a confined space.

Venting

Critical safety and operational requirements for furnace venting.

Gas Supply

Gas Supply and Piping

Covers important safety information, natural gas, and propane (LPG) supply.

Gas Pressure

Information and cautions regarding gas supply pressure.

Electrical Wiring

Electrical Connections

Details on making electrical connections, circuit requirements, and disconnects.

Accessories

Field Installed Optional Accessories

Lists and describes optional accessories like air cleaners and humidifiers.

High Altitude

Natural Gas at High Altitudes

Installation requirements and cautions for natural gas furnaces at high altitudes.

Start-Up Procedures

Sequence of Operations

Describes the step-by-step operation sequence for starting the furnace.

Fault Codes

Diagnostics and Fault Codes

Explains the 7-segment display and lists potential fault codes and their meanings.

Field Selections & Adjustments

Field Selections - Dipswitches

Explains how to use dipswitches for various field selections like blower delay and display orientation.

Adjusting or Checking Furnace Input

Procedures for adjusting and checking the furnace input rate.

Airflow

Temperature Rise Check

How to perform a temperature rise check to verify airflow and furnace operation.

Safety Features

Limit Control;HALC

Explanation of the high limit cut-off and reasons for it opening.

Maintenance

Annual Inspection

Recommendations for annual inspection of furnace components.

Diagnostics

Troubleshooting Guide

A flowchart and guide for troubleshooting furnace issues.

Wiring Diagram

Ruud 801S SERIES Specifications

General IconGeneral
BrandRuud
Model801S SERIES
CategoryFurnace
LanguageEnglish

Related product manuals