Transmitter
Operating Frequency
Indicators
Output Power
Load Matching
Operating Temperature
Battery Types
Battery Life
Disposable
Dimensions
Weight
Continuous
82 kHz • 8 kHz •815 Hz • Both
(815Hz/82kHz)
NORMAL HIGH
Automatic from 5 W to 2000 W
-4°F to 133º (-20ºC to +55ºC)
8-15 hours*
Battery Life Rechargeable
Continuous
10-20 hours*
815 Hz
8 kHz
82 kHz
Both
0.6W 2.0 W
0.6W 2.0 W
0.2W 1.0W
0.12W (AF)+ .06W 1.33W (AF) + 0.67W (RF)
Rechargeable
• 12V
• 7amp/hr
• maintenance free
• sealed lead acid battery
• 120VAC wall mount charger (included)
• 12V automotive power pack (optional)
Intermittent
40-60 hours*
25% duty cycle average
Intermittent
50-70 hours*
25% duty cycle average
Disposable
8 - “D” Duracell alkaline batteries
16” x 6.32” x 5”
40.6cm x 16cm x 12.7cm
8 pounds (3.6kg)
(“D” batteries)
11.5 pounds (5.2kg) (rechargeable battery)
*depending on load, frequency and power setting
AC Load Resistance Measurement
Low Bat Indicator
Low Bat warning modulated on output signal
every 20 seconds.
8879 Specifications