Do you have a question about the Ryobi R18PD5 and is the answer not in the manual?
Keep work area clean, well-lit, and free of hazards. Keep children away.
Warnings related to electrical hazards like grounding, water exposure, and cord safety.
Stay alert, use PPE, prevent unintentional starting, avoid overreaching, dress properly.
Do not force the tool, check switch operation, disconnect power before adjustments.
Use correct charger/battery to prevent fire risk and injury.
Keep batteries away from metal, avoid damage, and store properly.
Damaged batteries may cause fire or injury.
High temperatures can cause battery explosion.
Charge within specified temperature range to prevent damage/fire.
Use only identical replacement parts serviced by qualified personnel.
Battery servicing must be done by manufacturer or authorized providers.
Protect hearing from noise during impact drilling.
Use auxiliary handles for better control and to prevent injury.
Hold insulated surfaces; avoid drilling into hidden electrical wires.
Do not operate on materials that pose a health risk.
Stop tool immediately if bit stalls to prevent recoil and injury.
Be cautious of hidden utilities when drilling into structures.
Secure the workpiece for stable operation and to prevent movement.
Operate and store tool within specified temperature ranges.
Charge battery within the specified temperature range for optimal performance.
Keep tools, batteries, and chargers away from fluids to prevent short circuits and damage.
Use and store batteries within specified temperature ranges for optimal performance.
Transport batteries according to local and national provisions and regulations.
Wear ear protection and limit exposure to noise.
Wear protective eye shields or goggles during product use.
Limit exposure to vibration and follow risk reduction instructions.
Hold product by insulated surfaces to prevent shock.
Wear protection suitable for dust type to prevent respiratory injury.
Keep warm in cold weather and wear gloves to maintain hand warmth.
Exercise after operation to improve blood circulation.
Take breaks frequently and limit daily exposure to reduce vibration effects.
The LED work light indicates when electronic protections are activated.
Overload protection shuts down the drill; LED flashes 4 times.
Low voltage protection shuts down the drill; LED flashes 6 times.
Overheating protection shuts down the drill; LED flashes 10 times.
Disconnect power before any maintenance or adjustment to prevent accidental starting.
Use only identical parts for servicing to avoid hazards or damage.
Avoid contact of solvents and chemicals with plastic parts to prevent damage.
Wear safety goggles or glasses with side shields for eye protection.
For safety and reliability, have repairs done by an authorized service center.
Bearings are pre-lubricated for the product's lifespan under normal use.
Recycle materials and dispose of the machine and accessories responsibly.
e-Torque control automatically drives screws to a flush depth.
Indicates a safety alert symbol for potential hazards.
Indicates compliance with European health, safety, and environmental standards.
Indicates voltage and direct current measurements.
Indicates revolutions per minute, chuck capacity, and no-load speed.
Indicates conformity with Eurasian and Ukrainian regulations.
Symbols indicate drilling without impact, auto screw driving, and percussion drill modes.
Indicates proper disposal of electrical products for recycling.
Imminent hazard resulting in death or serious injury.
Potentially hazardous situation resulting in death or serious injury.
Potentially hazardous situation resulting in minor or moderate injury.
Situation that may result in property damage.
Indicates a note or important piece of information.
Indicates items that are not included with the product and are sold separately.
Identifies the product model and its voltage requirement.
Specifies the chuck size range and the type of switch used.
Details the speed in drill and percussion drill modes at low and high settings.
Specifies maximum torque and drilling limits for wood, metal, and masonry.
Provides tool weight with and without battery pack.
Details sound pressure and power levels measured to a standard.
Specifies vibration levels measured according to EN 60745 standard.
Lists compatible battery pack models not included with the tool.
Lists compatible charger models not included with the tool.
Warning regarding vibration emission levels and potential exposure risks.
Details the 24-month warranty period and option for extension via online registration.
Covers manufacturing faults but excludes misuse, unauthorized repairs, wear, and accessories.
Requires service at authorized stations; warranty valid in specific regions.
Provides a link to find updated lists of authorized service centers.
Declares product compliance with relevant European directives and harmonized standards.
Identifies the person authorized to compile the technical file.