5. AUXILIARY
FUNCTIONS
MENU
What you see
on the display
DescripƟon and Comments
Normal
Mode
Insp
Mode
Visibility
Condition
Range
Default
Value
Cabin Lock2 FL#
Sets the 2nd locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled & Cabin Lock1
FL# ≠ “ALL”
- ,0…31
-
Cabin Lock3 FL#
Sets the 3rd locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled & Cabin Lock2
FL# ≠ ” –“
- ,0…31 -
Cabin Lock4 FL#
Sets the 4th locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled & Cabin Lock3
FL# ≠ ” –“
- ,0…31 -
Cabin Lock5 FL#
Sets the 5th locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled & Cabin Lock4
FL# ≠ ” –“
- ,0…31 -
Cabin Lock6 FL#
Sets the 6th locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled & Cabin Lock5
FL# ≠ ” –“
- ,0…31 -
Cabin Lock7 FL#
Sets the 7th locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled & Cabin Lock6
FL# ≠ ” –“
- ,0…31 -
Cabin Lock8 FL#
Sets the 8th locked floor and its
corresponding passcode
NA
A
Car Panel
Lock Enabled & Cabin
Lock7 FL# ≠ ” –“
- ,0…31
-
Door LS EO/EC
When set to NONE, no limit switches are
installed for automac door. Door
closing/opening is controlled by “Auto
Door Operaon” me.
NA A Auto/½Auto door Installed/None Installed
SpreConfig. Ip
This parameter is to configure the IP3
spare input, Set this parameter to Final
SW to read the final limit switches status.
In this case, If the final limit switch is not
reached, the input is acve.
NA A N/A OverLoad/Final SW OverLoad
Final Switch Err
fault level can be:Level 2 / Level 3.
Aer final limit switch is reached and the
controller generates a “final switch error”,
when the fault is diagnosed and
corrected:
Level 2: The li performs a homing trip.
Level 3: The lift is blocked and needs
reset.
NA A
SpreConfig. Ip: Final
SW
Level 2 / Level 3 Level 3
VVVF Type
When “Other” is selected, the board will
give no outputs during evacuaon.
NA A VVVF drive
VX2/
Other
VX2
Board Address
Sets the address of the board (each board
in a group must have a uniqueaddress)
A A N/A 1 to 4 1
User Password Shows and edits the user password A A N/A ****** 000000
Co.
Shows and edits the company name
displayed on the first page
A A N/A 16 characters
Max Trips/h
Shows the maximum recorded count of
trips in one hour along with the time of
the day when it happened
A A N/A N/A
Adjust Time Sets the me of the day A A N/A
N/A
Adjust Date Sets the date A A N/A N/A
Adjust Day Sets the day of the week A A N/A Mon to Sun
Upload settings
to DT
Upload the settings from MicroZed to DT A A DT connected
Learning trip
Iniates a learning trip to calculate all
floor posions
A NA
VVVF drive & Encoder
installed
N/A
ManualFloor
adjustment
Allow manual floor posion adjustment A A
VVVF drive & Encoder
installed
N/A
Thisfeature is implemented in version 3.00.H and above.