5. AUXILIARY
FUNCTIONS
MENU
What you see
on the display
DescripƟon and Comments
Normal
Mode
Insp
Mode
Visibility
Condition
Range
Drive Selects the drive type NA A N/A
AC 2speed / Hydraulic /
VVVF
Intermediat
Speed
Selects when intermediate speed is used NA A
VVVF drive & Encoder
not installed
None, 1FL, 2FL
Homing Speed Select the homing speed NA A VVVF drive Insp/ Hi/ Int
Spare1 Sets the Spare1 output funcon NA A Not Hydraulic
Fan/Gong/BaseBlock/
DoorB Close/DoorB Open/
Int.Speed/Down Arrow/Up
Arrow/½Auto
cam/Hyd.Star/Car
Light/Open/CamClose/ Dn
Direcon/Up
Direcon/LowSpeed/ High
speed/Slowing Down/Evac
Mode/Insp Mode/Door
Buzzer /Out Of
Serv./OverLoad
Spare2 (24V) Sets the Spare2 output funcon NA A Not 1/2 Auto. door
Fan/Gong/ BaseBlock/
DoorB Close/DoorB Open/
Int.Speed/Down Arrow/Up
Arrow/½Auto
cam/Hyd.Star/Car
Light/Open/CamClose/ Dn
Direcon/Up
Direcon/LowSpeed/
Highspeed/Slowing
Down/Evac Mode/Insp
Mode/Door Buzzer /Out Of
Serv./OverLoad
Spare3 (24V) Sets the Spare3 output funcon NA A Same as Spare 2
Spare4 (24V) Sets the Spare4 output funcon NA A Same as Spare 2
CC+ o/p (24V) Sets the CC+ output funcon NA A
Collecve# Mul/
MulF
Same as Spare 2
CC- o/p (24V)
Sets the CC- output funcon
NA
A
Collecve# Mul/
MulF
Same as Spare 2
HC+ o/p (24V) Sets the HC+ output funcon NA A
Collecve# Mul/
MulF
Same as Spare 2
HC- o/p (24V) Sets the HC+ output funcon NA A
Collecve# Mul/
MulF
Same as Spare 2
CT Spare1 Sets the spare1 on CT output funcon A A Serial Calls:Car Same as Spare 2
CT Spare2 Sets the spare2 on CT output funcon A A Serial Calls:Car Same as Spare 2
CT Spare3 Sets the spare3 on CT output funcon A A Serial Calls:Car Same as Spare 2
CT Spare4 Sets the spare4 on CT output funcon A A Serial Calls:Car Same as Spare 2
Passenger
Capacity
Sets the passenger capacity of the
elevator
A A Group mode 1 to 99
Display Type Selects the hall and car display type A A N/A Gray / Binary / Enhanced
Total Trips
Counter for the number of trips made by
the elevator. The counter value can be
edited and modified
A A N/A 0 to 999999
Language Sets the language A A N/A
English/French / Arabic
/Swedish
Insp. Car Cmd
When this feature is enabled, The first
two calls in COP are used to move the li
in inspecon mode
A A N/A Disabled / Enabled
Access Control
When this feature is enabled, access to all
or specified floors is limited by a passcode
entered using the COP.
NA A
Serial Calls=None
&&CancellaonDisabl
ed
Disabled / Enabled
Cabin Lock1 FL#
Sets the 1st locked floor and its
corresponding passcode
NA A
Car Panel Lock
Enabled
ALL,0...31/
****
Output voltage level is 0Vdc when active on CarTop