8. MANUAL FLOOR ADJUSTMENT
8. MANUAL FLOOR ADJUSTMENT
Manual oor adjustment allows the installer to ne-tune the oor stopping position of the lift and should
only be done after learning trip procedure and distance calculation. Normally, if all DZ ags (or magnets) are
accurately positioned on the oor level, no additional oor tuning would be necessary. To manually adjust
the oor level, the following steps must be implemented:
1. Disable re-leveling feature.
2. Put lift in normal mode.
3. Give a car call to the lowest oor and record in a table the dierence in the oor stopping position
next to oor 0 and proceed by giving car calls to stop on all the oors in the building and on each stop
record the dierence in the oor stopping position next to the corresponding oor starting from oor1.
It is good practice to use positive values for stops lower than the oor position and to use negative values
for stops higher than the oor positions.
4. Repeat step 3 in the down direction.
5. Enter the menu and go to “Manual Floor Adjustment”.
6. On oor 0, edit the position when going in the down direction and add to it the value recorded in the
table next to oor0.
7. Repeat step 6 for all subsequent oors and for both stopping directions.
8. Give a car call to oor 0, Check the oor stopping position which should be correct by now.
9. Repeat step 8 for all subsequent oors.
10. Set Re-leveling to “Dist(mm) 10”
11. Set “Update counter” to “All oors”
8. MANUAL
FLOOR
ADJUSTMENT