8. MANUAL FLOOR ADJUSTMENT
8. MANUAL FLOOR ADJUSTMENT
Manual oor adjustment allows the installer to ne-tune the oor stopping position of the lift and should
only be done after learning trip procedure and distance calculation. Normally, if all DZ ags (or magnets) are
accurately positioned on the oor level, no additional oor tuning would be necessary. To manually adjust
the oor level, the following steps must be implemented:
1. Disable re-leveling feature.
2. Put lift in normal mode.
3. Give a car call to the lowest oor and record in a table the dierence in the oor stopping position
next to oor 0 and proceed by giving car calls to stop on all the oors in the building and on each stop
record the dierence in the oor stopping position next to the corresponding oor starting from oor1.
It is good practice to use positive values for stops lower than the oor position and to use negative values
for stops higher than the oor positions.
4. Repeat step 3 in the down direction.
5. Enter the menu and go to “Manual Floor Adjustment”.
6. On oor 0, edit the position when going in the down direction and add to it the value recorded in the
table next to oor0.
7. Repeat step 6 for all subsequent oors and for both stopping directions.
8. Give a car call to oor 0, Check the oor stopping position which should be correct by now.
9. Repeat step 8 for all subsequent oors.
10. Set Re-leveling to “Dist(mm) 10”
11. Set “Update counter to All oors”