This document describes the SD-45S2SB, a 6-in-1 comprehensive beauty machine designed for various body and facial treatments. It integrates RF&Suction, EMS&EL, RF&Ultrasound, and Lipo Laser technologies to provide professional beauty solutions.

Function Description:

The SD-45S2SB offers a range of functions for both facial and body care:

  • Skin Firming and Anti-ageing: This includes firming the face, deep nutrient introduction, increasing skin elasticity and smoothness, moisturizing, accelerating blood circulation and metabolism, relieving double chin, and stimulating collagen proliferation.
  • Firming for V-shaped Face: Similar to anti-ageing, with an added focus on shaping a V-shaped face and targeting unwanted fat on the neck.
  • Neck Care: Aims to relieve neck flabbiness, roughness, dullness, increase skin elasticity, firm skin, relieve double chin, accelerate lymphatic detoxification, improve facial texture, and prevent neck and lymph diseases.
  • Body Management:
    • Waist & Abdomen Shaping: Relieves cold hands/feet/womb/body, tightens waist and abdomen skin, reduces lumbar and abdominal fat, relieves stretch marks and obesity lines, increases skin elasticity, accelerates metabolism, relieves constipation, and improves intestinal peristalsis.
    • Arm Shaping: Stimulates collagen growth, improves sagging skin, and addresses flabby and thick arms.
    • Back Shaping: Relieves shoulder and back soreness, improves neck lumps, dredges channels and collaterals, increases blood circulation and metabolism, improves blood supply to the head and sleep, regulates visceral functions, strengthens the body, firms skin, prevents sagging, and reduces excess back fat.
    • Leg Shaping: Tightens skin, prevents sagging, stimulates collagen regeneration, improves fat lines, increases leg circulation and detoxification, promotes metabolism, removes blood stasis, dredges channels and collaterals, prevents varicose veins, and reduces protruding fat on legs and thick thighs.
    • Butt Shaping: Improves blood circulation and metabolism, relieves menstrual pain, irregular menstruation, abnormal leucorrhea, and other female diseases, improves sleep quality, female sexual function, and tightens the vagina, maintains normal ovary function, stimulates gland secretion, makes complexion ruddy, fades color spots, and shapes hips by improving sagging and outward expansion, tightening skin, and increasing elasticity.

Working Principles:

  • RF&Suction: This technology combines radiofrequency (RF) and vacuum suction. RF heats collagen cells in the dermis, stimulating collagen fiber growth for firmer, more elastic skin. The vacuum suction improves cellular fluidity, drains excess water, enhances microvessel blood circulation, removes harmful substances, strengthens blood vessels, repairs cells, increases skin elasticity, stimulates bone collagen production, improves oxygen absorption, breaks down cellulite fibers, and lowers skin sensitivity by stimulating the sympathetic nervous system. The integrated RF tips allow for independent or complementary use of RF and vacuum, offering more effective and even body shaping. The added red LED light helps kill bacteria and activate cells.
  • EMS&EL:
    • EMS (Electronic Muscle Stimulation): Directly conveys electrical signals to muscles, causing passive movements that firm the skin and enhance facial contours.
    • EL (Electroporation): Uses electrical pulses to create temporary pores in cell membranes, allowing larger or hydrophilic molecules to pass into cells, thereby promoting permeability.
  • RF&Ultrasound:
    • Ultrasound Cavitation: Uses ultrasonic waves to make human adipose cells vibrate, creating a strong impact and friction. This leads to the production of tiny bubbles and cavitation, which break down fat cells.
    • RF (Radiofrequency): Generates heat to promote collagen growth, tighten skin, and improve metabolism.
  • Lipo Laser: Uses red laser light (635nm-650nm) to penetrate through fat layers, causing fat cells to release fatty acids and glycerol, which are then transported through the lymphatic system for energy. This process is designed to reduce fat without side effects or pain.

Important Technical Specifications:

  • Ultrasound Cavitation 2.5 & RF Body Shape Handle:
    • Ultrasound Cavitation Frequency: 30KHz, Power: 50W
    • RF Frequency: 5MHz, Power: 85W
  • Suction & RF Body Sculpture Handle:
    • RF Frequency: 5MHz, Power: 85W
    • Suction Vacuum: <-80kPa, Pressure: >250kPa, Air flow: >10L/minute
    • Noise level: <70dB (30cm away), Power: 20W
  • Suction & RF Facial Slimming Handle:
    • RF Frequency: 5MHz, Power: 85W
    • Suction Vacuum: <-80kPa, Pressure: >250kPa, Air flow: >10L/minute
    • Noise level: <70dB (30cm away), Power: 20W
  • EMS & EL (Electroporation) Facial Anti-aging Handle:
    • EMS Frequency: 4.5KHz, Power: 10W
    • EL (Electroporation) Frequency: 65Hz, Power: 10W
  • General Specifications:
    • Net Weight: 7.60kg
    • Gross Weight: 25.08kg
    • Dimensions: 490x390x300 (mm)
    • Input Power: AC 110V/220V 50/60Hz
    • Power Consumption: MAX 150W
    • Display: Touch Screen

Usage Features:

  • Interface: The device features a touch screen display with intuitive controls for time adjustment, energy level settings, and mode selection.
  • Modes:
    • Ultrasound: Offers constant working mode (for thick fat accumulation) and discontinuous mode (for specific areas or consolidating treatment results).
    • RF: Provides fixed mode (RF energy directly reaches preset level) and smart mode (RF energy slowly reaches preset level).
    • Lipo Laser: Includes M1 (constant, for efficient fat reduction), M2 (discontinuous, low frequency, for consolidating results), and M3 (discontinuous, high frequency, for beginners or first-time users).
  • Adjustments: Users can adjust treatment time, energy levels for different technologies (Ultrasound, RF, EMS, EL), and suction/release times for vacuum treatments. Lipo laser pad energy levels can be adjusted individually.
  • Handpieces: The device comes with various handpieces for specific treatments: RF&Suction, EMS&EL, RF&Ultrasound, and Lipo Laser pads.
  • Treatment Protocols: Detailed operational diagrams and step-by-step instructions are provided for various treatments, including skin firming, V-shaped face firming, neck care, and body shaping (waist&abdomen, arms, back, legs, and butt). Each protocol specifies the handpiece to use, recommended time, energy levels, mode, and specific massage techniques.
  • Treatment Courses: A typical course of treatment consists of ten sessions, with recommendations for multiple courses to achieve and consolidate desired results.

Maintenance Features:

  • Safety Precautions:
    • Always use a grounded plug and ensure proper voltage.
    • Use only specified parts from the original manufacturer.
    • Avoid damp places, direct sunlight, or strong heat sources.
    • Remove all metal objects from the body before treatment.
    • Do not use on eyes, thyroid, parathyroid, testicles, abdomen of pregnant women, or pacemakers.
    • Patients with illnesses should consult a doctor.
    • Turn off the power switch after daily use.
    • Start with the lowest energy level and gradually increase.
  • Cleaning: Clean the instrument with normal saline after operation to ensure cleanliness and prolong service life.
  • Handle Usage: Handles can be used alone, but better results are achieved when used in conjunction with other handles.
  • Post-Operation Care: Specific instructions are provided for post-treatment care, such as avoiding hot water, staying hydrated, avoiding irritating products, maintaining a healthy lifestyle, and applying face masks. For body treatments, recommendations include keeping the treated area warm, avoiding certain foods and activities (e.g., sauna, strenuous exercise), and gentle massage.

Inapplicable Range:

The device should not be used on individuals with:

  • Recent plastic surgery with prostheses or metal implants.
  • Recent injections (hyaluronic acid, mesotherapy, wrinkle removal).
  • Hypertension, heart disease, diabetes, severe hyperthyroidism, malignant tumors.
  • Allergies, severely sensitive skin, or metal allergies.
  • Skin trauma or wounds.
  • Advanced age.
  • Menstruation, pregnancy, lactation, or surgical recovery.
  • Skin diseases or infectious diseases.
  • Sensitivity to electric currents.
  • Metal implants (stents, pacemakers).
  • Surgical wounds that are healing or convalescing.
  • Epilepsy, hemophilia, or severe bleeding.
  • Weakness, drunkenness, thirst, overwork, or on a full/empty stomach.
  • Severe varicose veins or tumors.
  • Recent liposuction.