STOP SOLENOID DESCRIPTION.
The stop solenoid has two coils, one for pull and one for
hold. When the stop button is pressed, both the pull and hold
coil are energised and the plunger retracts. As soon as it
"BOTTOMS", the internal switch disconnects the high current
winding, and the plunger is kept retracted by the hold coil.
The stop solenoid is secured by an automatic fuse (circuit
breaker), located in the relay box.
If the stop function fails, the reason is likely a blown fuse.
It should be reset by pressing the upper fuse button.