26
GB
dimensions of the gap to be cut in the kitchen unit.
• The panels located above the work surface, directly next to the
appliance, must be made of non-ammable material. Both the
stratied surfacing and the glue used to secure it should be
heat resistant, to prevent deterioration.
• Turn on appliance tap and light each burners.
• Check for a clear blue ame without yellow tipping.
• If burners shows any abnormalities check the following :
– Burner lid on correctly
– Flame spreader positioned correctly
– Burnervertically aligned with injector nipple
• A full operational test and a test for possible leakages must be
carried out by the tter after installation.
• The exible hose shall be tted in such a way that it cannot
come into contact with a moveable part ofthe housing unit
and does not pass through any space susceptible of becoming
congested.
• Grease cranes produced at the factory to meet the requirement
of all life hob.