2 Adjustment of minimum level of the ame.
1. Turn the taps down to minimum.
2. Remove the knob from the tap and place a small bladed
screwdriver in the centre of the tap shaft.
3. The correct adjustment is obtained when the ame has a
length of about 3 - 4 mm.
For butane/ propane gas, the adjusting screw must be
tightly screwed in.
Ret the control knob.
Make sure that the ame does not go out by quickly turning
from maximum ow to minimum ow. If it does then
remove the control knob and make further adjustments to
the gas ow, testing it again once the adjustment has been
made.
4. Repeat this process for each one of the gas taps.