27
TECHNICAL DATA
TYPE Saey 92 TR Saey 94 TR
Dimensions
- width C C/mm 710 644
- height H1 H1/mm 765 742
- depth T1 T1/mm 515 490
- depth T2 T2/mm 590 575
Discharge
- height H2 H2/mm 610 574
- diameter D D/mm 100 100
Gas connection
- height H3 H3/mm 622 589
- dimension S S/mm 243 212
- diameter "G 3/8" 3/8"
Gas control block TYPE EUROSIT+
Net calorific value (n.c.v.) kW 10,5 10,5
Nominal thermal output kW 8,9 8.,9
natural gas / propane
Nominal gas flow rate
- natural gas, methane G20 m3/h 1,110 1,110
- propane G31 kg/h 0,815 0,815
Nominal burner pressure
- methane mbar 17,5 17,5
- propane mbar 30 30
Burner pressure, economy pos.
- methane mbar 4,5 4,5
- propane mbar 15 15
- injector nozzle
- diameter methane mm 1,8 1,8
propane mm 1,25 1,25
- number methane - S180 S180
propane - S125 S125
- quantity - 2 2
Pilot light nozzle methane N° 48 48
propane N° 46 46
Flue gas discharge safety device N°
Therm – o – disc 10HG11 – Ex -221484