EasyManua.ls Logo

Saey 94 - Connecting the Stove to the Chimney; Procedure for Chimney Fire Events

Saey 94
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAEY 94 / SAEY 94 CUCINA
30042013 v03 32
ENGLISH
6.4 Connection of the stove to the chimney
The stove can be connected directly to the chimney.
The diameter of the chimney should match the diameter of the flue outlet of the appliance., Please note the following
regarding the diameter of the chimney:
The diameter of the chimney may not be reduced. Also, the flue outlet must fit the chimney perfectly.
If there is too much chimney draught, then a damper must be incorporated.
The chimney may not draw in extra air. Watch out for flue dampers and cleaning hatches in the cellar or on the
roof!
The flue outlet must be securely attached to the connector pipe.
6.5 What must I do in the event of a chimney fire?
We recommend that you take the following steps in the event of a chimney fire
1. Close off the air supply.
2. Call the fire brigade.
3. Clear access routes to the cleaning openings (e.g. cellar and attic).
4. Move all inflammable objects away from the chimney.
5. When the appliance is put back into service, the chimney and the stove should be checked over by a specialist.
6. This specialist should also investigate the cause of the chimney fire after and take any corrective measures.
SUGGESTION If you let the fire burn for 10 minutes each day at maximum power, this allows combustion
products to be burnt off. This reduces the risk of any chimney fire and also helps keep the
window cleaner.
50cm
20cm
20cm
80cm
ATTENTION!
It’s important that all parts of the chimney are fitted airtight.