19. Faults
Malfunctioning
Cause Solution
Wood too moist Check; max. residual moisture 20%
Wrong fuel Use only the fuel allowed for the appliance
Chimney draught too weak:
(Minimal pressure: 10Pa at the heating
gas connector pipe)
Check the air-tightness of the outlet
Light a kindling fire in the chimney
Close any open doors of other appliances
connected to the chimney.
Close the cleaning hatches of the chimney
If necessary, clean the connector pipe
The fire is not burning well
Not enough combustion air Connect the combustion air pipe directly to
the appliance, and convey combustion air
to the circulation grate or directly to the
outside
Check the diameter of the circulation
Check the ventilation installation of the
residence or cooker hood, and open a
window if necessary
Wood too moist Check; max. residual moisture 20%
Wrong fuel Fuel not small enough max.
circumference is 50 cm
Use only the fuel allowed for the appliance
Glass soon gets dirty
Too much wood has been added Do not add more than 2 to 3 pieces of wood