SafeLine EVAC v.2.1.0 EN
Technical data
Technical data main unit
Power: 24 VDC
In standby: 40 mA
Active: 120 mA
Inputs: 4 x 24 VDC, max 200 mA in total, optically isolated
Outputs: 3 x 24 VDC, max 200 mA
Size: Surface mounted: 418 x 116 x 40 mm (L x W x H)
Flush mounted: 400 x 110 x 40 mm (L x W x H)
Weight: 300 g - without frontplate
IP code: IP43
Technical data Floor station/car station
Power: 24 VDC
In standby: 30 mA
Active: 60 mA
Inputs: 2 x 24 VDC, max 100 mA, optically isolated
Outputs: 2 x 24 VDC, max 100 mA in total
IP code: IP43
Technical data LMS Unit
Power: 230 VAC
Inputs: 2 x 24 VDC, max 200 mA in total, optically isolated
Relay outputs: Max. 2 A/30 VDC, 0,5 A/125 VAC potential free relay contacts
PSU: max. 4 A at 24 VDC
Technical data bus cable
Max cable length: 200 meters - using 0,5 mm2 twisted pairs, shielded (recom-
mended).