2 - OPERATION
Installation and User Guide - N56717020101
No reproduction or communication without the written consent of
SAGEM SA
Page A2-7
Configuration parameters per functional blocks Default
value
Equipment – Continue
Alarms
Alarm severity
The severity of each alarm is configurable individually with the following
attributes: major, major reverse, minor, minor reverse, none, none reverse
See tables
2-9 to 2-11
Alarm Persistence
Persistence for the appearance: X = 1, 3, 10 or 30s
Persistence for the disappearance: Y = 01, 3, 10 or 30s
X = 3s
Y = 3s
Loops
Mismatch of remote indication loops 1 and 2 validated or not
(use of bits 1 to 4 of byte S1)
Not validated
Centre site (yes/no) No
Routing
Authorization to transmit traps to the management: declaration of the
manager addresses (10 addresses possible)
Tables of configured static routes Not configured
Putting ports into service: Ethernet, PPP1, PPP2, PPP3 or PPP4
Enabled / Disabled (port by port) Disabled
Port addressing (port by port) :
Interface IP address
Subnetwork mask
Destination IP address (PPP interface only)
0.0.0.0
0.0.0.0
0.0.0.0
Management paths (port by port – PPP only):
Options: MNGT, DCC1_A, DCC1_B, DCC1_C, DCC1_D Not configured
RIP routing validated or not (port by port) Not validated
Table 2-6 – Configuration parameters (6/6)