Proc Sheet 2 01
myC5-2
REMOVING/ REPLACING THE DATA/ AUDIO/
CHARGE CONNECTOR
2/3
________________________________________________________________________________________________
Ref. SCT U38 SSC DTS 0024 – Index B - February 15, 2005 Page 5-45
- Maintain the electronic board
- flux Correctly the pins of the connector.
- Reference of the flux to be used:
- LITTON flux -Supplier reference 952-D6
-SAGEM reference18 775 103-7
- With tweezers, hold the connector and heat the pins up.
ATTENTION:
-Do not pull the connector but let it come , in order to avoid
destroying the pads
After having removed the connector, uncork rather quickly the four
holes of the connector while the tin is still warm.
Flux and heat the pads in place of the connector to equalise the
foot prints
In order to tin the pins of the DATA/ AUDIO/ CHARGE
connector, load the solder wick with tin on approximately 1
inch.