Proc Sheet 1 06
myC5-2
REMOVING / REPLACING THE METAL DOME
1/2
Ref. SCT U38 SSC DTS 0024 – Index B - February 15, 2005 Page 5-22
4.41 Tools :
- Cross shaped screwdriver
- Gloves
- Metal dome Jig
Tweezers
4.42 Preliminary operation
This procedure must be performed by a technician with gloves.
1. Remove the battery pack ( Proc sheet 0 01).
2. Remove the back cover ( Proc sheet 1 01).
4.43 Removal procedure :
1. Remove the metal dome (2) of the equipped electronic board (1)
4.44 Placement procedure :
Warning : The metal dome is not reusable, it must be necessarily replaced by a new metal dome, unless the
board is swapped and sent as level 3
1. Replace the new metal dome (2) on the equipped electronic board (1), using the metal dome jig.
2. Place the equipped electronic board in its housing
4.45 Further operations :
1. Replace the back cover ( Proc sheet 1 01).
2. Replace the battery pack ( Proc sheet 0 01).
3. Carry out the radio test (Test Sheet 04).

Other manuals for Sagem myC5-2