Proc Sheet 1 12
myC5-2
REMOVING / REPLACING THE VIBRATING
DEVICE
1/2
Ref. SCT U38 SSC DTS 0024 – Index B - February 15, 2005 Page 5-35
4.72 Tools :
- Cross shaped screwdriver
- Soldering iron
- Solder wick
- Flat screwdriver
4.73 Preliminary operation
1. Remove the battery pack ( Proc sheet 0 01).
2. Remove the front flip cover ( Proc sheet 1 07).
4.74 Removal procedure :
1. Remove the vibrating device (1) from its housing first with a flat screwdriver
2. Unsolder the vibrating device (1) on the equipped display (2)
3. Remove the vibrating device (1)
4.75 Placement procedure :
1. Flux the place of the vibrating device (1) and solder it on the equipped display (2), respecting the wiring sense
2. Position the vibrating device (1) in its housing
4.76 Further operations :
1. Remove the front flip cover ( Proc sheet 1 07).
2. Remove the battery pack ( Proc sheet 0 01).