SAILFISH 272 CC | FISHBOX PUMP
The 272CC is equipped with a diaphragm pump called the gulper grouper.
(pictured top right). The Whale Gulper Grouper pump has no impeller to clog or
burn out. Unlike impeller pumps these have no-choke valves that easily pump
out sh box waste. They also o󰀨er long term durability, they can run dry without
causing damage.
This pump will pump both sh boxes through a system called a ooded T
(pictured bottom right) The ooded T allows both boxes to have a centralized
drainage location that can be operated by a single pump.
Troubleshooting
Electric Motor Runs but doesn’t pump
Disconnect pump and turn o󰀨 all power.
Disconnect hoses and unscrew housings.
Check entire hose system for blockage.
Inspect tricuspid valves for blockage or inverted valve(s).
If valve(s) are blocked, remove blockage, re-assemble the pump and continue use.
If a tricuspid valve is inverted, replace with a new tricuspid valve, reassemble the pump
and continue use.
If the electric motor will not operate, check that:
The isolator switch is on.
There is 12 volts at the battery terminals.
The in-line fuse / circuit breaker are operational.
If the fuse / circuit breaker has blown, check for debris in pump head and clean out if neces-
sary. Replace the fuse or re-set circuit breaker and run the pump.