PDS33 Series
- 31 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
frequency
type
F0.18
Acceleration
time 1
0.0s 6500.0s
0.1s
Due to
type
F012
F0.19
Deceleration
time 1
0.0s 6500.0s
0.1s
Due to
type
F013
F0.20
Default setting
0:Not restore to default
setting
1: Restore to factory
setting
2:Fault record clearing
1
0
F014
F2 GroupMotor Parameters
F2.01
Motor rate
power
0.1KW 400.0KW
0.1KW
Due to
type
F201
F2.02
Motor rate
voltage
1V 440V
1V
Due to
type
F202
F2.03
Motor rate
current
0.01A 655.35A
<=55KW
0.1A 6553.5A
>55KW
0.01A/
0.1A
Due to
type
F203
F2.04
Motor rate
frequency
0.01Hz Max
frequency
0.01Hz
Due to
type
F204
F2.05
Motor rate
speed
1rpm 36000rpm
1rpm
Due to
type
F205
F4 GroupVF control
F4.00
V/F curve
setting
0:Straight line V/F
curve
2:2.0th power low torque
V/F curve
1
2
F400
F4.01
Torque boost
0.1% 30.0%
0.1%
Due to
type
F401
F4.02
Cut-off
frequency
0.00HzF0.10
0.01Hz
50.00Hz
F402
F5 GroupInput Terminals
F5.00
Function of
DI1
0No function
1Forward runFWD
4Forward JOGFJOG
1
1
F500
F5.01
Function of
DI2
1
4
F501