PDS33 Series
- 48 -
6.3 Description of controller’s status and faults
Description
Communication
address
Command content
Attributes of
read or write
Controller’s
status
3000H
0001FWD running
0002REV running
0003Stand-by
0004Fault
0005Under voltage
0006Exchanging between
R
Controller’s
fault
8000H
0000No error
0001Reserved
0002Over current during
acceleration
0003Over current during
deceleration
0004 Over current at
constant speed
0005Over voltage during
acceleration
0006Over voltage during
deceleration
0007 Over voltage at
constant speed
0008 Overload of buffer
resistor
0009Under voltage error
000AController overload
000BMotor overload
000CInput phase loss
000DOutput phase loss
000EModule overheat
000FExternal error
0010 Communication
abnormal
0011Relay failure
R