PDS33 Solar Pump Controller
User Manual
Version code6.0004.0358-00-PDS33-E-V03-1907

Questions and Answers

  • P
    Patricia NelsonSep 18, 2025
    What to do if SAJ Controller shows running time reached?
    • J
      Jody MillerSep 18, 2025
      If the SAJ Controller indicates that the running time has reached the set value, restore factory settings.
  • K
    khaleAug 25, 2025
    What to do if my SAJ Controller shows a controller overload error?
    • T
      Troy CampbellAug 25, 2025
      If the SAJ Controller displays a 'Controller overload' error, it could stem from several causes. The acceleration might be too rapid, so try increasing the acceleration time. It is also possible that the input voltage is too low, requiring you to check the input power supply and wiring. If the motor was restarted immediately after a trip-off, avoid doing this. Lastly, the load might be too heavy, suggesting the need to replace with a higher-rating controller.
  • J
    Jeffrey PriceAug 25, 2025
    Why is my SAJ Controller overheating?
    • R
      Raymond HurstAug 26, 2025
      If your SAJ Controller is overheating, it could be due to several reasons. There might be an instantaneous over-current, so refer to the over-current remedy. Another potential cause is an output short circuit, requiring re-wiring of the output. The ambient temperature could also be too high; if possible, decrease it. Check for loose cables or terminals and tighten them. If the power circuit is abnormal, ask for support.
  • K
    Kimberly HaleAug 26, 2025
    What causes a communication fault in SAJ Controller?
    • K
      Kelly WilliamsAug 27, 2025
      If you are experiencing a communication fault with your SAJ Controller, there are a few things you can check. First, ensure that the baud rate is set correctly. Second, verify that the upper machine is working normally. Finally, inspect the communication devices and cables for any long-time communication interruptions.
  • B
    Bradley SmithSep 18, 2025
    What to do if SAJ Controller shows powering time reached?
    • B
      Bryan FordSep 18, 2025
      If the SAJ Controller indicates that the powering time has reached the set value, restore factory settings.
  • P
    pwrightSep 23, 2025
    What causes EEPROM checking failure on SAJ Controller?
    • N
      Natalie WhiteSep 23, 2025
      If the SAJ Controller shows EEPROM checking failure, it is because the EEPROM is damaged, so ask for technical support.
  • O
    Oscar WalkerSep 9, 2025
    What causes an output phase loss on a SAJ Controller?
    • S
      Stephen GravesSep 9, 2025
      If the SAJ Controller shows an output phase loss, it could be due to broken wires in the output cable, so check the wiring and installation.
  • L
    lynn51Sep 10, 2025
    What causes overload of buffer resistor in SAJ Controller?
    • R
      rmejiaSep 10, 2025
      If the SAJ Controller experiences overload of the buffer resistor, it is due to abnormal input voltage, so adjust input voltage to normal range.
  • E
    Elizabeth FosterSep 3, 2025
    What causes over-voltage during acceleration in SAJ Controller?
    • J
      John ClarkSep 3, 2025
      If the SAJ Controller shows an over-voltage during acceleration, it may be due to abnormal input voltage, so check input power. Another cause could be restarting the motor when instantaneous trip-off occurs; avoid prompt restart when trip-off.
  • K
    kristinamitchellSep 1, 2025
    Why am I getting over-current at constant running speed on my SAJ Controller?
    • J
      Jennifer MaySep 1, 2025
      If the SAJ Controller experiences an over-current at constant running speed, a sudden change of load may have occurred, so check the load. Also, the input voltage might be too low, so check the input power supply or wiring.

Summary

Notes for Safe Operation

Installation and Operation Safety

Critical safety warnings and guidelines during installation and operation.

Chapter 1 How It Works

Chapter 2 General Information

Protection Features

Explanation of the controller's electronic monitoring and automatic shutdown features.

Chapter 3 Mechanical and Electrical Installation

Electrical Installation Procedures

Detailed steps for wiring power, motor, and control signals.

Chapter 4 Start-up and Operation

Chapter 5 Diagnostics and Troubleshooting

Fault Code Reference

List of error codes, their descriptions, possible causes, and remedies.

Chapter 6 Protocol

Chapter 7 Regular Maintenance

Chapter 8 Backup AC Power

SAJ PDS33-2S2R2 Specifications

General IconGeneral
Max. DC Voltage1100 V
THDI< 3%
Max. Efficiency98.6%
MPPT Efficiency99.9%
DC ConnectionMC4
Weight12kg
Dimensions350x260x130mm
MPPT Voltage Range200 V - 1000 V
Frequency50 Hz / 60 Hz
Operating Temperature Range-25°C to 60°C
CommunicationWiFi/GPRS