PDS33 Series
- 30 -
4.4 User Definable Parameters
○:The parameters can be modified at stop or running status.
●:The parameters cannot be modified at running status.
The parameters which are actual-detecting record value and cannot be
modified.
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
F0 GroupBasic Function
F0.01
Start/stop
signal option
0KeypadLED off
1TerminalLED on
2RS485
CommunicationLED
Flickering
1
0
F001
F0.03
Main
frequency
source
1 F0.08Knob and
UP/DOWN available
2AI1
3AI2
8MPPT
9Communication
1
8
F003
F0.08
Keypad set
frequency
0.00Hz Max F0.10
0.01Hz
50.00Hz
F008
F0.09
Running
direction
0FWD
1REV
1
0
F009
F0.10
Max output
frequency
50.00Hz 320.00Hz
0.01Hz
50.00Hz
F00A
F0.12
Up limit
frequency
F0.14 F0.10
0.01Hz
50.00Hz
F00C
F0.14
Low limit
frequency
0.00Hz F0.12
0.01Hz
0.00Hz
F00E
F0.15
Use of low
limit frequency
When set frequency is
lower than low limit
frequency,
0Run at low limit
frequency
1Stop
2Run at 0.00Hz
1
0
F00F
F0.16
Carrier
0.5kHz 16.0kHz
0.1kHz
Due to
F010