PDS33 Series
- 30 -
4.4 User Definable Parameters
○:The parameters can be modified at stop or running status.
●:The parameters cannot be modified at running status.
◎ : The parameters which are actual-detecting record value and cannot be
modified.
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
F0 Group:Basic Function
F0.01
Start/stop
signal option
0:Keypad(LED off)
1:Terminal(LED on)
2:RS485
Communication(LED
Flickering)
1
0
●
F001
F0.03
Main
frequency
source
1: F0.08(Knob and
UP/DOWN available)
2:AI1
3:AI2
8:MPPT
9:Communication
1
8
○
F003
F0.08
Keypad set
frequency
0.00Hz ~Max F0.10
0.01Hz
50.00Hz
○
F008
F0.09
Running
direction
0:FWD
1:REV
1
0
○
F009
F0.10
Max output
frequency
50.00Hz ~ 320.00Hz
0.01Hz
50.00Hz
●
F00A
F0.12
Up limit
frequency
F0.14 ~F0.10
0.01Hz
50.00Hz
○
F00C
F0.14
Low limit
frequency
0.00Hz ~F0.12
0.01Hz
0.00Hz
○
F00E
F0.15
Use of low
limit frequency
When set frequency is
lower than low limit
frequency,
0:Run at low limit
frequency
1:Stop
2:Run at 0.00Hz
1
0
○
F00F
F0.16
Carrier
0.5kHz ~ 16.0kHz
0.1kHz
Due to
○
F010