PDS33 Series
- 36 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
FD.24
MPPT flag
/
/
0
FD18
FD.25
MPPT
voltage added
0.0V1.0V
0.1V
0
FD19
FE GroupParameters management
FE.00
User password
0 65535
1
0
FE00
FE.01
Fault
record display
times
0 15
1
5
FE01
E0 GroupCurrent fault record
E0.00
Type of
current fault
record
0No error
1Reserved
2Over current during
accelerationErr02
3Over current during
decelerationErr03
4Over current at
constant speedErr04
5Over voltage during
accelerationErr05
6Over voltage during
decelerationErr06
7Over voltage at
constant speedErr07
8Overload of buffer
resistorErr08
9Under voltage error
Err09
10Controller overload
Err10
11Motor overload
Err11
12Input phase loss
Err12
13Output phase loss
Err13
14Module overheat
Err14
15External error
Err15
E000