4-5. No HDMI Video
Symptom The LED power turns on but the screen is blank when the BNC cable is connected.-
Major
checkpoints
Check the BNC cable connections.
Check whether the LVDS cable is connected correctly to the panel.
Check whether the lamp connector of the panel is connected correctly to the IP board.
-
-
-
Diagnostics
CN401
C603
IC302
CN101
IC201
R214,R215
CN201
Yes
Press the power button and
check the LED.
No
Does the LED light up when turn on
the power?
Does 5V appear at Pin 19 of C201 DVI
port?
Reconnect the BNC cable.
No
Yes
Does the signal appear at R214(SCL_
HD) ⑦ and 215(SDA_HD) ⑧?
Replace IC102.
No
Yes
Does the TX** signal appear at Pin 16
and 17 of CN401?
The scaler (IC302) is
abnormal.
Replace the main board.
No
Yes
Check the cable between the main
board and panel and
replace the LCD panel.
Does the signal appear at R214(DDC_
SCL_DOUT) and R215(DDC_
SDA_DOUT) ?
The IC302 is abnormal.
Replace the main board.
No
Yes
Caution Make sure to disconnect the power before working on the IP board.