EasyManua.ls Logo

Samsung 730MP - Disassembly and Reassembly; 3-1 Disassembly

Samsung 730MP
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Disassembly and Reassembly
730MP 3-1
3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
MH17FS LCD Monitor.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
3-1 Disassembly
Cautions: 1. Disconnect the monitor from the power source before disassembly.
2. When IP-BOARD has a defect, the whole PCB ASS’Y, not a single part, should be
replaced.
3. R/Cover opening jig : BH81-00001A
1. Place the monitor face down on cushioned
table. Remove 1 screw and remove wiselink from
the Monitor.
2. Remove 3 screws from girp on the stand and
remove back cover. While pressing the back cover,
lift up the stand.
(See Illustrations)
3. Disconnect function cable from the shield and
remove 9 screws and 2 connectors from the shield.
4. Lift up the shield PCB and disconnect inverter
holder from the PCB board.
!
!
connector