AIR CONDITIONER CONTENTS
SYSTEM AIR CONDITIONER
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram
6. Wiring Diagram
7. Reference Sheet
AC026MNNDKH
AC035MNNDKH
AC052MNNDKH
AC060MNNDKH
AC071MNNDKH
AC026MXADKH
AC035MXADKH
AC071MXADKH
Mini 4 WAY CASSETTE SERIES
INDOOR UNIT OUTDOOR UNIT
Model :
AC026MNNDKH
AC035MNNDKH
AC052MNNDKH
AC060MNNDKH
AC071MNNDKH
AC026MXADKH
AC035MXADKH
AC052MXADKH
AC060MXADKH
AC071MXADKH
AC052MXADKH
AC060MXADKH

Questions and Answers

  • L
    Lindsey FisherSep 14, 2025
    What causes error E153 on a Samsung Air Conditioner?
    • A
      anthony13Sep 14, 2025
      Error code E153 on your Samsung Air Conditioner indicates an issue with the indoor unit's float switch, possibly an open or short circuit related to drain pump operation. Check the float switch (2nd detection).
  • F
    fnelsonAug 25, 2025
    What to do if my Samsung AC026MNNDKH wireless remote control does not operate?
    • R
      rodriguezgaryAug 25, 2025
      If your Samsung Air Conditioner's wireless remote control isn't working, first check if the batteries are discharged and replace them with new ones. Ensure that nothing is blocking the remote control sensor. Strong light from fluorescent bulbs or neon signs may interfere with the remote control, so check for any nearby.
  • D
    Dalton WeaverAug 25, 2025
    Why is my Samsung Air Conditioner not cool or warm enough?
    • M
      monica83Aug 26, 2025
      If your Samsung Air Conditioner isn't cooling or warming enough, check the set temperature. In Cool mode, if the set temperature is higher than the current temperature, cool air won't come out. Press the Temperature button to set it lower (minimum 18°C). In Heat mode, if the set temperature is lower than the current temperature, warm air won't come out. Press the Temperature button to set it higher (maximum 30°C).
  • R
    Rhonda SchultzAug 26, 2025
    Why warm air does not come out of the Samsung AC026MNNDKH?
    • S
      Scott AriasAug 26, 2025
      Warm air may not be coming out of your Samsung Air Conditioner if the outdoor unit is designed for cooling only. In this case, warm air won't come out even if you select the Heat mode. Also, ensure that the remote control supports both cooling and heating. If it doesn't, use a remote control that does.
  • M
    Marisa GarzaSep 15, 2025
    How to troubleshoot error E198 on a Samsung AC026MNNDKH Air Conditioner?
    • L
      littletammieSep 15, 2025
      If your Samsung Air Conditioner displays error code E198, which indicates a Thermal Fuse Open, check the indoor unit Terminal Block.
  • C
    Cynthia CunninghamSep 23, 2025
    What to do for unpleasant odours permeate the room from my Samsung AC026MNNDKH Air Conditioner?
    • T
      Travis KirkSep 23, 2025
      If unpleasant odors are coming from your Samsung Air Conditioner, and the unit is running in a smoky area or there's a smell from outside, ventilate the room. If indoor temperature and humidity are high, operate the air conditioner in Clean or Fan mode for 1 to 2 hours. If the unit hasn't been used for a while, clean the indoor unit and operate it in Fan mode for 3 to 4 hours to dry the inside. Also, clean the air filter if it's blocked with dirt.
  • D
    dustin67Sep 7, 2025
    What to do if my Samsung AC026MNNDKH Air Conditioner shows error E202?
    • P
      Patricia MorrisSep 7, 2025
      If your Samsung Air Conditioner displays error code E202, the suggested solution is to check the electrical connection and settings between the indoor and outdoor units.
  • J
    Jeremy HamiltonSep 8, 2025
    What to do if my Samsung Air Conditioner displays error code E121?
    • A
      Amanda ManningSep 8, 2025
      If your Samsung Air Conditioner shows error code E121, it indicates an issue with the indoor unit's room thermistor, specifically an open or short circuit. Check the room temperature sensor of the indoor unit for shorts or opens.
  • D
    David RodriguezSep 2, 2025
    How to troubleshoot error on discharge temperature sensor of compressor 1 in Samsung Air Conditioner?
    • Z
      zachary56Sep 2, 2025
      If your Samsung Air Conditioner is showing an error related to the discharge temperature sensor of compressor 1, indicating a short or open circuit, you should check the discharge sensor for any open or short conditions.
  • C
    Cynthia PetersAug 31, 2025
    How to fix communication error between the outdoor unit and main micom on Samsung Air Conditioner?
    • D
      David RubioAug 31, 2025
      If you encounter a communication error between the outdoor unit and the main micom on your Samsung Air Conditioner, especially on PF #4 to #6 controllers, you should check the electrical connection and setting between the indoor unit MAIN PBA and the INVERTER PBA.