Technical specifications
Cleaning and Maintenance
Technical specifications
Type Model Net weight (kg) Net dimension (W x D X H) (mm)
Indoor unit
AC026RNNDKG 11.5 575 x 575 x 250
AC035RNNDKG 11.5 575 x 575 x 250
AC052RNNDKG 12.0 575 x 575 x 250
AC071RNNDKG 12.0 575 x 575 x 250
Information about refrigerant
Important information: regulation regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
CAUTION
• If the system contains 5 tCO
2
e or more of fluorinated greenhouse gases, it must be checked
for leakage at least once every 12 months, according to regulation No. 517/2014. This activity
must be covered by qualified personnel only. In the case of the situation above, the installer (or
authorized person with responsibility for final check) must provide a maintenance book, with
all the information recorded, according to REGULATION (EU) No. 517/2014 OF THE EUROPEAN
PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on fluorinated greenhouse gases.
This indoor unit can be connected to an R-32 or R-410A outdoor unit.
R-32: Single / DPM
R-410A: DPM only (available with AC200/250KXAPNH)
Refrigenat type GWP value
R-32 675
R-410A 2088
• GWP: Global Warming Potential
• Calculating tCO
2
e: kg x GWP/1000