Reference Sheet
Samsung Electronics 7-3
CONDENSER
High temperature and high pres sure gas state coolant discharged from the compr e ssor is converted to a liquid state as it is cooled
down by the heat emission in the outdoor condenser unit, and sent to the evaporator.
COMPRESSOR
Low temperature
and low pressure coolant is compressed and sent to the cycling system
EVAPORATOR
Liquid coolant sucked in through the capillary tubes cools down the room by absorbing the surrounding heat as it evaporates
(conv
erting from liquid to gas). (Absorbing heat required for evaporation)
SERVICE VALVE
You can open the valve by turning the need valve counterclockwise using hex wrench, and it is used for vacuum, gas purging, coolant
injection, coo
lant purging, and indoor-outdoor unit connection.
ACCUMULATOR
Accumulator prevents the flow of liquid-state coolant into the compressor. (Liquid-state coolant flowing into the compressor will
overload the c ompr e ssor.)
Indoor Unit
Outdoor Unit
Heat exchanger
Evaporator
Liquid pipe
Gas pipe
3-way valve
3-way valve
Electronic expansion valve
Compressor
Oil separator
4-way valve
Cooling
Heating
Leak check points
Aux accumulator
Fan
Heat exchanger
Evaporator
Fan
7-2 Refrigerating Cycle Diagram