EasyManua.ls Logo

Samsung AC160JNHFKH - Troubleshooting; Indoor Display Error and Check Method

Samsung AC160JNHFKH
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 4-1
4. Troubleshooting
4-1 Indoor Display Error and Check Method
Error detection and reoperation
If error occurs during the operation, badness is indicated by LED flickering and all operation is stopped except LED.
When reoperating by remote control and switch determine the error mode after normal operation.
4-1-1 Indoor unit LED lamp display at error detecting
LED Display on the receiver & display unit
Abnormal conditions
Indicators
Remarks
Concealed
Type
GREEN RED
Standard Type
Power reset
X X X X
Error of Room sensor in the indoor unit(Open/Short)
X X X X
Error of EVA-IN,EVA-OUT discharge sensor in the indoor
unit(Open/Short)
X X X
Error of Fan motor in the indoor unit
X X X X
1. Error of Outdoor
2. Thermal Fuse Open Error of Indoor's Terminal Block
X X
1. Clogging of outdoor's service valve
2. the refrigerant leakage
X X
Detection of the float switch
X X X
1. Error of EEPROM
2. Error of Option setting
1. Error of Outdoor Temp. sensor
2. Error of Cond Temp. sensor
3. Error of discharge Temp. sensor
X X X
1..No communication for 2 minutes between indoor
units (Communication error for more than 2 minutes)
2. Indoor unit receiving the communication error from
outdoor unit
3. Outdoor unit tracking 3 minutes error
4. When sending the communication error from the
outdoor unit, the mismatching of the communication
numbers and installed numbers after completion of
tracking.(Communication error for more than 2 min-
utes)
X X X
1. Indoor unit
error
(Display is unre-
lated
with operation)
2. Outdoor unit
error
(Display is unre-
lated
with operation)
If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
On
Flickering
X
Off

Table of Contents