Troubleshooting
4-64 Samsung Electronics
4-4-20 SPI Feedback Error
Indoor unit display
(Operation)
(Timer)
×
(Fan)
(Filter)
×
(Defrost)
t SPI defect
Criteria
Cause of problem
t Check if the output of SPI Feedback is 12V
Outdoor unit display
1. How to check
Is the SPI connector of an
indoor unit separated from PCB?
Connect the connector to PCB
and reoperate
Yes
No
Replace Main PCB
Can you measure 12V from
#1, #4 power with SPI connector
being connected?
Replace SPI
No
Yes
#1 #4