Troubleshooting
4-36 Samsung Electronics
- Big Ceiling
Ŷ Error detection and reoperation
ƔIf error occurs during the operation, badness is indicated by LED flickering and all operation is stopped except LED.
ƔIf you re-operate the air conditioner, it operates normally at first, then detect an error again.
ŶIndoor unit LED lamp display at error detecting
Error mode
Product operation with error
Remarks
Blue Green Orange Red
Power reset
ስ ΉΉΉ
0.5[S]=On, O.5[S]=Off
Operation on
م ΉΉΉ
Operation off
ΉΉΉΉ
-
Reservation
Ή م ΉΉ
-
Filter sign
ΉΉم Ή
-
Defrosting
ስ ΉΉΉ
1[S]=On, 9[S]=Off
Communication error between indoor
units
Ή ስ ΉΉ
-
EEPROM error / EEPROM option error
ስ ΉΉስ
-
Error of temperature sensor in indoor
unit(open/short)
ΉΉΉስ
-
Error of outdoor Unit/ Self-Diagn osis
ΉΉስ Ή
-
Error of the indoor Unit pipe sensor
Ή ስ Ή ስ
Indoor fan error
ስስ ΉΉ
Thermal Fuse open error
ስ Ή ስ Ή
Indoor unit float S/W 2nd detection
Ή ስስ Ή
: On : Flickering : Off
- If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
- If you re-operate the air conditioner,it operates nomally at first,then detects an error again.
- If the LED displays olny one color, it is turned on for a second and turned off for a second.
- If the LED displays more than two colors, each color is shown for a second alternately.