Cooling Capacity | 3.6 kW |
---|---|
Heating Capacity | 4.0 kW |
Energy Efficiency Class (Cooling) | A++ |
Energy Efficiency Class (Heating) | A+ |
Refrigerant | R32 |
Power Supply | 220-240V, 50Hz |
Type | Split System |
COP | 4.0 |
Procedures for setting indoor unit options and addresses using the remote controller.
Explains LED lamp displays for error detection in cassette type indoor units.
Main PCB No Power Phenomenon.
Troubleshooting steps for the main PCB when there is no power.
Diagnosing and resolving indoor unit room sensor errors (Open/Short).
Troubleshooting EVAP IN sensor errors (Open/Short).
Diagnosing EVAP OUT sensor errors (Open/Short).
Troubleshooting EVAP IN sensor dislocation errors in indoor heat exchangers.
Diagnosing EVA OUT sensor dislocation errors in indoor heat exchangers.
Troubleshooting simultaneous EVA IN/OUT sensor dislocation errors.
Diagnosing EEV opening malfunction errors (2nd stage), including causes and checks.
Troubleshooting E153 error related to the indoor unit drain pump's floating switch.
Troubleshooting for errors related to the operational status of the indoor unit's fan motor.
Troubleshooting steps for EEPROM errors, including PCB replacement.
Troubleshooting for simultaneous opening errors of Cooling/heating MCU SOL valves.
Steps to diagnose and resolve errors from incorrect indoor unit power or communication cable connections.
Troubleshooting for SPI feedback errors, including PCB and SPI replacement.
Procedures for inspecting outdoor unit piping and diagnosing errors.
Troubleshooting communication errors between indoor and outdoor units during tracking.
Diagnosing communication errors that occur after tracking indoor and outdoor units.
Troubleshooting communication errors between main and sub outdoor units.
Diagnosing communication errors between the MCU and outdoor unit.
Troubleshooting internal communication errors within the outdoor unit's C-Box.
Diagnosing internal PCB communication errors within the outdoor unit's C-Box.
Troubleshooting communication errors between MCU and outdoor units after tracking is completed.
Addressing MCU branch part setup errors related to inconsecutive connection of two branch parts.
Troubleshooting MCU branch part setup errors due to repeated address setup.
Diagnosing MCU branch part setup errors when an indoor unit address is not installed on the MCU.
Troubleshooting MCU branch part setup errors related to incorrect MCU quantity configuration.
Addressing MCU branch part setup errors caused by overlapping indoor unit addresses.
Troubleshooting MCU branch part setup errors where a part is used without connecting to an indoor unit.
Troubleshooting MCU branch part setup errors due to connecting more indoor units than configured in the MCU.
Troubleshooting steps for outdoor temperature sensor errors (Open/Short).
Diagnosing outdoor temperature sensor dislocation errors.
Troubleshooting for Cond Out Temperature Sensor errors (Open/Short).
Diagnosing Outdoor Cond Out sensor breakaway errors.
Troubleshooting for digital compressor discharge temperature sensor errors.
Diagnosing constant rate compressor discharge temperature sensor errors.
Troubleshooting compressor discharge or top temperature sensor errors.
Troubleshooting suction temperature sensor breakaway errors.
Diagnosing sump sensor errors (OPEN/SHORT).
Troubleshooting high pressure sensor errors (Open/Short).
Diagnosing low pressure sensor errors (Open/Short).
Troubleshooting suction temperature sensor errors (Open/Short).
Diagnosing liquid pipe temperature sensor errors (Open/Short).
Diagnosing EVI In Temperature sensor errors (Open/Short).
Troubleshooting EVI Out Temperature sensor errors (Open/Short).
Diagnosing suction-2 temperature sensor errors (OPEN/SHORT).
Diagnosing compressor down issues due to high pressure protection control.
Troubleshooting compressor down issues related to low pressure protection control.
Diagnosing sump sensor errors due to protection control.
Diagnosing and resolving 3-phase input wiring errors.
Diagnosing compressor down issues related to compression ratio control.
Diagnosing compressor starting errors, checking bypass valves and resistance.