Do you have a question about the Samsung AM050FXMDGH and is the answer not in the manual?
Type | Air conditioner outdoor unit |
---|---|
Multi-split | - |
Product color | White |
Compressor type | Twin Rotary |
Gas hose diameter | 15.88 mm |
Hose length (max) | 175 m |
Hose length (min) | 150 m |
Liquid hose diameter | 9.52 mm |
Refrigerating medium | R410A |
Air conditioner functions | Cooling, Heating |
Cooling capacity (nominal) | 47800 BTU/h |
Heating capacity (nominal) | 54600 BTU/h |
Refrigerating medium weight | 3200 g |
Heating capacity in watts (max) | 16000 W |
Cooling capacity in watts (nominal) | 14000 W |
Cooling energy efficiency (EER, W/W) | 4.43 |
Heating energy efficiency (COP, W/W) | 3.8 |
Operating temperature (cooling) (T-T) | -5 - 48 °C |
Operating temperature (heating) (T-T) | -20 - 26 °C |
Heating capacity in watts (nominal) (Warmer heating season) | - W |
AC input voltage | 380 - 415 V |
Current (cooling) | 6.2 A |
Current (heating) | 6 A |
AC input frequency | 50 Hz |
Design load (cooling) | - kW |
Power consumption (cooling) (max) | 3610 W |
Power consumption (heating) (max) | 3680 W |
Hourly energy consumption (cooling) | - kWh |
Indoor unit noise level (high speed) | - dB |
Outdoor unit noise level | 51 dB |
Outdoor unit sound power level | 67 dB |
Provides detailed technical specifications for the product.
Explains the memory module's function for faster diagnosis and repair.
Guides on diagnosing and resolving system issues.
Details automatic checks for operation and refrigerant levels.
Lists all error codes and their descriptions.
Troubleshoots communication errors between units during tracking.
Troubleshoots communication errors after tracking is complete.
Troubleshoots 1-minute communication errors between outdoor unit micoms.
Troubleshoots errors related to outdoor temperature sensors.
Troubleshoots high pressure sensor errors (open/short).
Troubleshoots compressor shutdown due to antifreeze control.
Troubleshoots compressor shutdown due to high pressure protection.
Troubleshoots compressor shutdown due to low pressure protection.
Troubleshoots compressor issues related to discharge temperature sensor.
Troubleshoots reverse phase detection errors in 3-phase units.
Troubleshoots ESC EEV open errors.
Troubleshoots refrigerant leakage errors.
Explains compressor operation prohibition due to outdoor temperature.
Troubleshoots outdoor unit fan errors.
Troubleshoots compressor shutdown due to OLP temperature control.
Troubleshoots compressor starting and rotation errors.
Continues troubleshooting for compressor starting/rotation errors.
Troubleshoots current and PFC overload errors.
Troubleshoots IPM over current errors.
Continues troubleshooting for IPM over current errors.
Troubleshoots DC-Link voltage under/over errors.
Continues troubleshooting for DC-Link voltage errors.
Provides troubleshooting steps for various system symptoms.
Troubleshoots low pressure sensor errors (open/short).
Troubleshoots refrigerant leakage errors during operation.
Steps to troubleshoot "Undetermined" results for indoor unit sensors.
Explains the function for detecting refrigerant amount automatically.