Do you have a question about the Samsung AM050FXMDEH and is the answer not in the manual?
Type | Air conditioner outdoor unit |
---|---|
Multi-split | - |
Product color | White |
Compressor type | Twin Rotary |
Gas hose diameter | 15.88 mm |
Hose length (max) | 150 m |
Inverter technology | Yes |
Liquid hose diameter | 9.52 mm |
Refrigerating medium | R410A |
Air conditioner functions | Cooling, Heating |
Cooling capacity (nominal) | 47800 BTU/h |
Heating capacity (nominal) | 54600 BTU/h |
Refrigerating medium weight | 3200 g |
Heating capacity in watts (max) | 16000 W |
Cooling capacity in watts (nominal) | 14000 W |
Cooling energy efficiency (EER, W/W) | 3.79 |
Heating energy efficiency (COP, W/W) | 4.43 |
Operating temperature (cooling) (T-T) | -5 - 48 °C |
Operating temperature (heating) (T-T) | -20 - 26 °C |
Heating capacity in watts (nominal) (Warmer heating season) | - W |
AC input voltage | 220-240 V |
Current (cooling) | 17.8 A |
Current (heating) | 17.2 A |
AC input frequency | 50 Hz |
Power consumption (cooling) (max) | 3680 W |
Power consumption (heating) (max) | 3610 W |
Hourly energy consumption (cooling) | - kWh |
Design load (heating) (Warmer heating season) | - kW |
Indoor unit noise level (high speed) | - dB |
Outdoor unit depth | 330 mm |
Outdoor unit width | 940 mm |
Outdoor unit height | 1210 mm |
Outdoor unit weight | 100000 g |
Outdoor units quantity | 1 |
Outdoor unit noise level | 51 dB |
Outdoor unit package depth | 426 mm |
Outdoor unit package width | 995 mm |
Outdoor unit package height | 1388 mm |
Outdoor unit package weight | 105000 g |
Heating airflow (outdoor unit) | 10 m³/h |
Outdoor unit sound power level | 68 dB |
Details the various features of the outdoor unit, including performance and design.
Provides comprehensive technical specifications in tabular format for various models.
Procedures for removing cabinet parts like Front RH, Top, and Install Front panels.
Steps to remove the fan and motor assemblies from the outdoor unit.
Identifies error display location on PCB and lists common error codes.
Schematic showing wiring connections for 1-phase models, illustrating PCB and component links.
Schematic showing wiring connections for 3-phase models, illustrating PCB and component links.
Details the steps and purpose of the system check operation for diagnosing unit status.
Explains the process and actions for automatic refrigerant amount detection and judgment.