EasyManua.ls Logo

Samsung AQ09T Series - Cable Connection Details; Connecting Wires to Terminals and Grounding

Samsung AQ09T Series
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
29
2 . Open the front grille.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
5 . Pass the other end of the cable through the 65mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the front grille.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
• Eachwireislabeledwiththecorrespondingterminalnumber.
• Eachwireislabeledwiththecorrespondingterminalnumber.
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
09/12/18
24
Indoor unit
Outdoor unit
Ground wire
(Green/Yellow)
Ground wire
(Green/Yellow)
Indoor unit
Outdoor unit
Ground wire
(Green/Yellow)
Ground wire
(Green/Yellow)
• Endofthewiremustbecircular.
• Afterconnectingthecables,makesureterminalnumbersontheindoor/outdoorunitmatches.
• Screwsonterminalblockmustnotbeunscrewedwiththetorquelessthan12kgf•cm.
10. Connect the grounding conductor to the grounding terminals.
11. Close the terminal board cover by tightening the screw carefully.
• InRussiaandEurope,consultwiththesupplyauthoritytodeterminethesupplysystemimpedancebefore
installation.
• Connectthewiresrmlysothatwirescannotbepulledouteasily.
(If they are loose, it could cause burn-out of the wires.)
• Connectthewiresaccordingtocolorcodes,referringtothewiringdiagram.
• Thepowercableandtheinterconnectioncableshouldbeselectedaccordingtothespecicationinpage28.