Do you have a question about the Samsung AQN18VFUAGM and is the answer not in the manual?
Cooling Capacity | 5.0 kW |
---|---|
Power Supply | 220-240V, 50Hz |
Refrigerant | R32 |
Indoor Unit Noise Level (Min) | 26 dB(A) |
Outdoor Unit Dimensions (WxHxD) | 880 x 638 x 310 mm |
Capacity | 18000 BTU |
EER | 3.21 |
COP | 3.61 |
Operating Temperature (Cooling) | -10°C to 46°C |
Operating Temperature (Heating) | -15 to 24°C |
Essential safety measures to follow during installation and operation for equipment safety.
Guidelines for reading the manual, storing it, and understanding unit compatibility.
Ensures power supply compliance with safety standards and proper circuit breaker installation.
Criteria for selecting an indoor unit location, focusing on airflow and distribution.
Specifies clearances and dimensions for installing one outdoor unit.
Specifies clearances and dimensions for installing more than one outdoor unit.
Lists accessories included with the air conditioner for indoor and outdoor units.
Lists general and test operation tools required for installation.
Instructions for determining pipe/hose hole position and drilling it on the installation plate.
Details cable types, AWG, and cross-sectional areas for power and assembly cables.
Guidelines for electrical work, compliance, and terminal connections.
Precautions for terminal block wiring, ensuring secure connections to prevent fire hazards.
Instructions for connecting electrical cables to terminals on both indoor and outdoor units.
Guide on connecting refrigerant pipes between indoor and outdoor units using flare connections.
Instructions for modifying pipe length and adding refrigerant if necessary.
Procedure for purging the indoor unit with inert gas and checking for leaks.
Steps to alter the drain hose direction and verify for any leakage.
Instructions for installing a drain plug and hose on the outdoor unit for condensation drainage.
Procedure for purging air from refrigerant pipes and connecting them to outdoor unit valves.
Guidance on refrigerant charging based on pipe length and model, with cautions.
Information on refrigerant type, GWP, Kyoto Protocol, and proper filling of the refrigerant charge label.
Procedures for charging refrigerant using a liquid pipe, considering cylinder types.
Methods for performing gas leak tests on both indoor and outdoor units using a leak detector.
Steps for collecting refrigerant into the outdoor unit before disconnecting for repair or removal.
Steps for insulating pipes, wrapping cables, and securing the indoor unit onto the installation plate.
Instructions for mounting the outdoor unit on a stable base, ensuring it's level and secured.
Detailed guide on how to connect extended power cables using specific tools and materials.